Power Fit
®
Elite & Power Fit
®
Elite Deluxe
5
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS –
FOR HOUSEHOLD/RESIDENTIAL USE ONLY
• NOTE:
The
Power Fit
is fitted with a Quick-
Release Magnetic Power Cord.
•
DO NOT USE WITH ANY OTHER ELECTRICAL
OUTLET
or modify the plug.
•
The
Power Fit
has been designed for use with
a 3-prong, 120V dedicated electrical outlet only.
Always attach electrical cord to the
Power Fit
before plugging the Unit into an outlet. Plug into
a 3-prong wall outlet with no other appliances on
the same outlet. Plugging other appliances into
the outlet may cause the circuit to overload.
•
In the event of Unit malfunction, disconnect the
Power Cord quickly from the Unit with a gentle tug
where it is connected to the Unit.
•
Never tug the plug forcefully from the wall outlet.
•
NEVER USE WITH AN EXTENSION CORD.
A detachable power-supply cord is provided to
reduce the risk from becoming entangled in or
tripping over a longer cord.
•
A short power supply cord is provided to reduce
risk of becoming entangled or presenting a
tripping hazard.
Always attach electrical cord to the
Power Fit
before
plugging the Unit into an outlet. Plug into a 3-prong
wall outlet with no other appliances on the same
outlet. Plugging other appliances into the outlet will
cause the circuit to overload. If the electrical circuit is
overloaded with other appliances, your Unit may not
operate properly.
CAUTION: Attaching the Power Cord
Grounding Instructions
This product must be grounded. If it should
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This product is equipped with
a cord that has an equipment-grounding conductor
and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
DANGER:
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check
with a qualified electrician or serviceman if you are in
doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product – if
it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
This product is for use on a
nominal 120-V circuit and has
a grounding plug that looks like
the plug illustrated in
Fig. A
.
Make sure that the product is
connected to an outlet having
the same configuration as the
plug. No adapter should be
used with this product.
Fig. A
PF_IB_TP_ENG_V1_191206.indd 5
12/6/19 5:42 PM