Inverter/Charger DC Volt: 12
Twin 00 (2/0)
Watts
6
4
2
0
00 (2/0)
(RV2012OEM & RV3012OEM only)
500
15 ft
25 ft
39 ft
62 ft
79 ft
158 ft.
700
11 ft
18 ft
28 ft
44 ft
56 ft
112 ft.
1000
N/R
12 ft
20 ft
31 ft
39 ft
78 ft.
2000
N/R
N/R
N/R
16 ft
20 ft
40 ft.
2400
N/R
N/R
N/R
13 ft
16 ft
32 ft.
3000
N/R
N/R
N/R
10 ft
13 ft
26 ft.
†
N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance)
Minimum Recommended DC Cable Sizing Chart
†
Use in conjunction with DC wiring connection instructions in the Battery Connection section.
Specifications
(English)
Model Number:
RV750ULHW
RV1250ULHW
RV2012UL
RV2012OEM
RV3012OEM
Series Number:
AGAP5088
AGAP5094
AP5626
AGAP200012MVP3
AGAP4669
AC Input Connection:
Hardwire
Hardwire
Hardwire
Hardwire
Hardwire
INVERTER
Common Specifications for All Models: •
DC Input Volts (Nominal): 12 VDC • · DC Input Voltage Range: 10 - 15 VDC • Output Volts (Nominal): 120 VAC, ± 5% • Output Frequency (Nominal): 60 Hz, ± 0.5% • Efficiency: 88% to 94%,
depending on load and temperature
Tripp Lite Inverter/Chargers include a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users to set the minimum load level at which the unit’s
inverter turns on. Users can significantly reduce the No Load DC Input Current (approximately 1 to 3 A for all models) to a very low amp level with the use of this control.
Continuous Power (@ 20 C ):
750
1250
2000
2000
3000
OverPower
™
Peak Surge Power:*
1125
1875
3000
3000
4500
DoubleBoost
™
PeakSurgePower:*
1500
2500
4000
4000
6000
Maximum Output AC Current
6.3 A
10.4 A
16.7 A
16.7 A
25 A
Continuous
UL-Recognized DC Fuse
125 A
200 A
two 175 A
two 175 A
two 275 A
Required
DC Input Current @
Nominal V DC Full Load:
73 A
117 A
190 A
185 A
282 A
BATTERY CHARGER
Common Specifications for All Models •
Acceptance Volts VDC: (Wet** / Gel) 14.4 V** / 14.2 V • Float Volts DC (w/gel): 13.3 V (13.6 V) • · Input Volts (Nominal): 120 VAC
Charging Capacity DC:
45 A** / 11 A
55 A** / 14 A
100 A** / 25 A
100 A** / 25 A
140 A** / 35 A
Input Current AC:
8.2 A
11 A
20 A
21 A
25 A
LINE VAC OPERATION
Common Specifications for All Models •
Input Frequency (Nominal): 60 Hz, ±10% • Maximum Input Volts (Transfer to Battery) 145 VAC Except OEM Models (Selectable 145V**/135V)
Minimum Input Volts:
Selectable 75**, 85, 95 or 105 VAC
Selectable 75**, 85, 95 or 105 VAC
Selectable 75**, 85, 95 or 105 VAC
Selectable 75**, 85, 95 or 105 VAC
Selectable 75**, 85, 95 or 105 VAC
Transfer to Battery
Maximum Input AC Current
30 A
33 A
38 A
43 A
30 A
(Continuous, Charger at Maximum):
Maximum Bypass AC Current:
20 A
20 A
30 A
20/20 A
20/20 A
* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting.
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
Wire Gauge vs. Maximum Distance from Unit to Battery
Note on Labeling
Two symbols are used on the RV labels.
V~
: AC Voltage
V
: DC Voltage
1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com