TMCM-3314 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.10 • 2019-JAN-25
83 / 144
14
RunRight :
16
RORA 0
RSUB
18
MotorStop :
20
GAP 2, 0
JC ZE , MotorIsStopped
22
MST 0
MotorIsStopped :
24
RSUB
Binary form of CALL LT, RunLeft
(assuming RunLeft at address
100)
Field
Value
Target address
01
h
Instruction number
50
h
Type
06
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
64
h
Checksum
BB
h
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany