TMCM-3314 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.10 • 2019-JAN-25
119 / 144
Number
Global Parameter
Description
Range [Units]
Access
76
Serial host
address
Host address used in the reply telegrams
sent back via RS485.
0. . . 255
RWA
77
Auto start mode
0 - Do not start TMCL application after
power up (default).
1 - Start TMCL application automatically af-
ter power up.
0/1
RWA
81
TMCL code
protection
Protect a TMCL program against disassem-
bling or overwriting.
0 - no protection
1 - protection against disassembling
2 - protection against overwriting
3 - protection against disassembling and
overwriting
When
switching
off
the
protection
against
disassembling
(changing
this
parameter from 1 or 3 to 0 or 2, the
program will be erased first!
0/1/2/3
RWA
82
CAN heartbeat
Heartbeat for CAN interface.
If this time
limit is up and no further command is re-
ceived the motor will be stopped. Setting
this parameter to 0 (default) turns off the
CAN heartbeat function.
0. . . 65535
RWA
83
CAN secondary
address
Second CAN ID for the module. Switched
off when set to zero.
0. . . 2047
RWA
84
Coordinate
storage
0 - coordinates are stored in RAM only (but
can be copied explicitly between RAM and
EEPROM)
1 - coordinates are always also stored in the
EEPROM
0/1
RWA
85
Do not restore
user variables
Determines if TMCL user variables are to be
restored from the EEPROM automatically on
startup.
0 - user variables are restored (default)
1 - user variables are not restored
0/1
RWA
87
Serial secondary
address
Second module (target) address for RS485.
Setting this parameter to 0 switches off the
seconndary address.
0. . . 255
RWA
128
TMCL application
status
0 - stop
1 - run
2 - step
3 - reset
0. . . 3
R
129
Download mode
0 - normal mode
1 - download mode
0/1
R
130
TMCL program
counter
Contains the address of the currently exe-
cuted TMCL command.
R
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at