TMCM-3314 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.10 • 2019-JAN-25
86 / 144
3.6.44
ROLA (Rotate Left using the Accumulator Register)
Rotate in left direction (decreasing the position counter) using the velocity specified by the contents of the
accumulator register. The velocity is given in microsteps per second (pulse per second [pps]).
Internal function:
• First, velocity mode is selected.
• Then, the content of the accumulator is copied to axis parameter #2 (target velocity).
Related commands:
RORA, MST, SAP, GAP.
Mnemonic:
ROLA
<
axis
>
Binary Representation
Instruction
Type
Motor/Bank
Value
50
0 (don’t care)
0. . . 2
0 (don’t care)
Reply in Direct Mode
Status
Value
100 - OK
don’t care
Example
Rotate left motor 0, velocity specified by accumulator.
Mnemonic:
ROLA 0.
Binary Form of ROLA 0
Field
Value
Target address
01
h
Instruction number
32
h
Type
00
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
00
h
Checksum
33
h
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at