TMCM-3314 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.10 • 2019-JAN-25
131 / 144
Motor Velocity [pps]
Load Angle [µSteps]
SAP 108
SAP 109
SAP 110
SAP 111max. 90°
Field Weakening
Normal Closed Loop
max. 180°
Figure 14: Field Weakening
• SAP 111: Closed Loop Beta
• SAP 110: Closed Loop Gamma
• SAP 108: Gamma Vmin
• SAP 109: Gamma Vmax
6.3.5
Position Catch up
The TMCM-3314 includes a special feature for closed-loop positioning. Positioning parameters like velocity
and acceleration will be calculated to reach a position in a dedicated time. If the target trapezoidal ramp
cannot be maintained due to high load peaks the TMCM-3314 includes a special position catch-up mode
to ensure that the position will still be reached in time if possible.
Motor Velocity [pps]
Position
SAP 119
SAP 119
Overload
Catch-up
PID control parameters for catch-up
SAP 115, 116, 117, 118
Figure 15: Position Catch up
6.4
StallGuard2
The module is equipped with motor driver chips that feature load measurement. This load measurement
can be used for stall detection. StallGuard2 delivers a sensorless load measurement of the motor as well