TMCM-3314 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.10 • 2019-JAN-25
93 / 144
3.6.50
SAPX (Set Axis Parameter, Axis specified by X Register)
The SAPX command nearly works the same way as the
command, except that the axis number is
specified by the X register.
This command is mainly intended for use in standalone mode.
Info
For a table with parameters and values which can be used together with this
command please refer to section
Internal function:
The specified value is written to the axis parameter specified by the parameter number.
Related commands:
GAPX, AAPX.
Mnemonic:
SAPX <parameter number>, <value>
Binary representation
Binary Representation
Instruction
Type
Motor/Bank
Value
16
see chapter
(don’t care)
<value>
Reply in Direct Mode
Status
Value
100 - OK
don’t care
Example
Set the maximum positioning speed for the motor specified by the X register to 51200 pps.
Mnemonic:
SAPX 4, 51200.
Binary Form of SAPX 4, 51200
Field
Value
Target address
01
h
Instruction number
10
h
Type
04
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
C8
h
Value (Byte 0)
00
h
Checksum
DD
h
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany