TMCM-1021 TMCL
™
Firmware Manual • Firmware Version V1.42 | Document Revision V1.10 • 2018-JAN-09
70 / 109
3.7.35
RETI (Return from Interrupt)
This command terminates an interrupt handling routine. Normal program flow will be continued then.
This command is intended for use in standalone mode only.
An interrupt routine must always end with a RETI command. Do not allow the normal program flow to run
into an interrupt routine.
Internal function:
The saved registers (accumulator, X registers, flags and program counter) are copied
back so that normal program flow will continue.
Related commands:
EI, DI, VECT.
Mnemonic:
RETI
Binary Representation
Instruction
Type
Motor/Bank
Value
38
<interrupt number>
0 (don’t care)
0 (don’t care)
Reply in Direct Mode
Status
Value
100 - OK
don’t care
Example
Return from an interrup handling routine.
Mnemonic:
RETI
Binary Form of RETI
Field
Value
Target address
01
h
Instruction number
26
h
Type
FF
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
00
h
Checksum
27
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at