Firmware Manual • Firmware Version V1.42 | Document Revision V1.10 • 2018-JAN-09
77 / 109
Number
Axis Parameter
Description
Range [Units]
Access
6
Maximum
current
Motor current used when motor is running. The
maximum value is 255 which means 100% of
the maximum current of the module.
The current can be adjusted in 32 steps:
0. . . 7
79. . . 87
160. . . 167
240. . . 247
8. . . 15
88. . . 95
168. . . 175
248. . . 255
16. . . 23
96. . . 103
176. . . 183
24. . . 31
104. . . 111
184. . . 191
32. . . 39
112. . . 119
192. . . 199
40. . . 47
120. . . 127
200. . . 207
48. . . 55
128. . . 135
208. . . 215
56. . . 63
136. . . 143
216. . . 223
64. . . 71
144. . . 151
224. . . 231
72. . . 79
152. . . 159
232. . . 239
The most important setting, as too high values can
cause motor damage.
0. . . 255
RW
7
Standby
current
The current used when the motor is not running.
The maximum value is 255 which means 100% of
the maximum current of the module. This value
should be as low as possible so that the motor
can cool down when it is not moving. Please see
also parameter 214.
0. . . 255
RW
8
Position
reached flag
This flag is always set when target position and
actual position are equal.
0/1
R
9
Home switch
state
The logical state of the home switch input.
0/1
R
10
Right limit
switch state
The logical state of the right limit switch input.
0/1
R
11
Left limit
switch state
The logical state of the left limit switch input.
0/1
R
12
Right limit
switch disable
0 - switch activated
1 - switch deactivated
0/1
RWE
13
Left limit
switch disable
0 - switch activated
1 - switch deactivated
0/1
RWE