TMCM-1021 TMCL
™
Firmware Manual • Firmware Version V1.42 | Document Revision V1.10 • 2018-JAN-09
29 / 109
3.7.5
SAP (Set Axis Parameter)
With this command most of the motion control parameters of the module can be specified. The settings
will be stored in SRAM and therefore are volatile. That is, information will be lost after power off.
Info
For a table with parameters and values which can be used together with this
command please refer to section
Internal function:
The specified value is written to the axis parameter specified by the parameter number.
Related commands:
GAP, AAP.
Mnemonic:
SAP <parameter number>, <axis>, <value>
Binary representation
Binary Representation
Instruction
Type
Motor/Bank
Value
5
see chapter
0
<value>
Reply in Direct Mode
Status
Value
100 - OK
don’t care
Example
Set the maximum positioning speed for motor 0 to 51200 pps.
Mnemonic:
SAP 4, 0, 51200.
Binary Form of SAP 4, 0, 51200
Field
Value
Target address
01
h
Instruction number
05
h
Type
04
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
C8
h
Value (Byte 0)
00
h
Checksum
D2
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.