All Global Parameters of the TMCM-1021 Module in Bank 0
Number
Global Parameter
Description
Range [Units]
Access
65
RS485 baud rate
0
9600
Default
1
14400
2
19200
3
28800
4
38400
5
57600
6
76800
7
115200
8
230400
0. . . 8
RWA
66
Serial address
Module (target) address for RS485.
1. . . 255
RWA
67
ASCII Mode
Configure the TMCL ASCII interface:
Bit 0
0 - start up in binary (normal) mode
1 - start up in ASCII mode
Bits 4 & 5
00 - Echo back each character
01 - Echo back complete command
10 - Do not send echo, only send com-
mand reply
0. . . 63
RWA
68
Serial heartbeat
Serial heartbeat for RS485 interface. If this
time limit is up and no further command is
received by the module the motor will be
stopped. Setting this parameter to 0 (de-
fault) turns off the serial heartbeat function.
0. . . 65535
RWA
75
Telegram pause
time
Pause time before the reply via RS485 is
sent. For use with older RS485 interfaces it
is often necessary to set this parameter to
15 or more (e.g. RS485 adapters controlled
by the RTS pin). For CAN interface this pa-
rameter has no effect!
0. . . 255
RWA
76
Serial host
address
Host address used in the reply telegrams
sent back via RS485.
0. . . 255
RWA
77
Auto start mode
0 - Do not start TMCL application after
power up (default).
1 - Start TMCL application automatically af-
ter power up.
0/1
RWA
79
End switch
polarity
0 - normal polarity
1 - reverse polarity
0/1
RWA
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.