Installation Guide for SecureMesh® CONN-2000 - PL-0689A
Appendix A. RJ45 Cable Assembly
This appendix provides information on the RJ45 cable assembly. Use the steps below
to prepare the RJ45 cable to be inserted into the plug housing and then crimp.
Assembly Steps
1. Prepare the end of the cable by first stripping back the outer jacket to expose
one of the conductors.
Figure 18:
The Stripped Outer Jacket
2. Fold back the shielded braid and drain wire, so that they lay flat over the outer
jacket.
3. (Optional): If the cable has a foil shield, it can be folded back over the braid.
Otherwise it can be trimmed away.
4. (Optional): For cables with a foil shield, ensure that when the shield is folded
back over the outer jacket, its conductive side comes in contact with the
plug’s grounding clip.
Note:
When crimped, the grounding clip must form a 360
degree contact with either the braid and or the foil.