Installation Guide for SecureMesh® CONN-2000 - PL-0689A
Status
Checklist Item
Description
surge suppressor to the ground system on the utility pole
or building. Use a 10 AWG or larger down-lead.
Outdoor Ethernet
Cable
When installing the outdoor Ethernet cable, use the UV-
protected, STP, CAT5e (or better) cable that includes a
properly terminated drain wire.
l
In
cable segments #5 and #7 do
not need to be shielded.
l
For increased protection, run the CAT5e
(or better) cable through a grounded metal-
lic conduit installed on the mounting pole
or tower.
Connector Components
through
show the accessory parts of the CONN-2000 kit.
displays additional PoE injectors that are sold separately.
L-Bracket
One adjustable L-bracket part, as displayed below.
Figure 3:
Adjustable L-bracket