Trikdis GV14 Скачать руководство пользователя страница 14

14 

IN2:<Text> 
OUT:<Text> 

IN2 input restoration; 
OUT output restoration. 
E.g.: 

123456 TXTR IN2:2-o input restoration

 

16 

SETP 

 
+370xxxxxx 
+370xxxxxx,<Name> 

Entering of user name and their phone number: 
User phone number (16 symbols max); 
User phone  name (13 symbols max). 
E.g.: 

123456 SETP +31xxxxxx

 

E.g.: 

123456 SETP +31xxxxxx,Name

 

17 

DELP 

 
+370xxxxxx 
<Name> 

Deleting a user phone number: 
User phone number; 
User name 
E.g.: 

123456 DELP +370xxxxxx

 

E.g.: 

123456 DELP Name

 

18 

OUT 

 
ON 
OFF 

Changing the outputstatus: 
Changing output status to ON; 
Changing output status to OFF. 
E.g.: 

123456 OUT OFF

 

19 

LISTA 

 

An SMS query for an Administrator list in SMS to be sent. 
SMS message containing of an Administrator list will be sent. 
E.g.: 

123456 LISTA

 

20 

LISTU 

 

An SMS query for a User list in SMS to be sent. 
SMS message containing of a User list will be sent. 
E.g.: 

123456 LISTU

 

Automatics control 

Phone call 

1.

 

Call to the controller GV14 using a SIM card number. 

2.

 

Control command will be implemented immediately after the controller rejects the call.  

 

SMS message 

Note: Phone number must be on the controller‘s 

administrator 

list.  

1.

 

Send SMS message: 
Example: 

123456 OUT OFF 

 

to turn the output relay to the state 

off

Example: 

123456 OUT ON 

 

to turn the output relay to the state 

on

2.

 

Wait  until you receive  the confirmation of command implementation (if specified during the 
configuration): 

Command OK

    

command implemented; 

Wrong Password

  

wrong password; 

Wrong Command

  

wrong command; 

Wrong Data

  

 

wrong parameters; 

Fatal Error

  

 

controller error (this response cannot be described by the user) 

 

 

Содержание GV14

Страница 1: ...CONTROLLER GV14 User Manual Draugystes g 17 LT 51229 Kaunas E mail info trikdis lt www trikdis lt...

Страница 2: ...Controller installation 5 Wiring diagrams 7 Configuration using software TrikdisConfig 7 Connecting to a computer 7 Configuration of controller operation 8 User list 9 Administrator list 10 Recording...

Страница 3: ...st c mode Administrator controller output relay contacts may be switched by those whose phone number is on the administrator list Memory of 5 administrator and 1000 user names and their phone numbers...

Страница 4: ...command e g next phone call Memory Up to 5 administrator names and their phone numbers Up to 1000 user names and their phone numbers Inputs 2 IN1 and IN2 Set for NO resistance 10 k or NC resistance 0...

Страница 5: ...SM signal level 30 7 flashes Critical error in the parameters structure 8 flashes Error in the user phone number list structure POWER denotes controller power supply OFF No power supply Green light No...

Страница 6: ...t interruption If these indications are not as such see section Light indication 8 Check if the automatics can be controlled using a phone call call the SIM card number of the controller 9 Send these...

Страница 7: ...rameters are set using computer software TrikdisConfig Software may be found on www trikdis lt Connecting to a computer 1 Connect the controller to the computer USB slot using a USB cable e g USB type...

Страница 8: ...atus Done is displayed after every successful reading or saving action GV14 Product name SN Controller serial number BL Controller firmware boot loader version FW Controller firmware version HW Contro...

Страница 9: ...eration mode a Level relay contacts status is switched to other command status e g other phone call once controller receives a control command b Impulse relay contacts status is switched to the opposi...

Страница 10: ...rst administrator may only be edited and cannot be deleted Controller will not work if not a single administrator phone number is entered and control for the users will be denied Select the encoding l...

Страница 11: ...3 Click Disconnect to disconnect the programmed device Updating the controller firmware Manufacturer may improve the operation of controller GV14 and release a new controller firmware version Every u...

Страница 12: ...3456 password SETAP command APNR1 37068700000 parameters Commands sent in SMS messages No Command Contents Description 1 RESET Resetting controller GV14 E g 123456 RESET 2 INFO Inquiring about the con...

Страница 13: ...events Sending test messages Sending responses to command SMS E g 123456 SETAE APNR1 IN1 ON IN2 ON OUT ON TEST OFF ACK ON 12 SETAN APNR1 Name APNR2 Name APNR3 Name APNR4 Name APNR5 Name Entering of a...

Страница 14: ...trator list will be sent E g 123456 LISTA 20 LISTU An SMS query for a User list in SMS to be sent SMS message containing of a User list will be sent E g 123456 LISTU Automatics control Phone call 1 Ca...

Страница 15: ...GV14 Object name entered in the field Object name Power 24 5V Power supply in voltage Signal 90 Signal level in percent IN1 OK False IN1 input status circuit intact circuit is broken IN2 OK False IN2...

Страница 16: ...ce known to the maintenance specialists Device is disconnected from the electrical network by turning off the automatic fuse Warranty and limitation of liability The manufacturer provides a 24 month w...

Отзывы: