background image

15 

Controller SMS messages  

Controller  will  send  SMS  messages  to  the 

administrators 

once  a  controller  event  takes  place  or 

controller receives a control message via SMS.  

Every time 12 V power supply voltage is turned on, 

administrators 

are send a SMS message: 

 

SMS text 

Description 

Dev: GV14 

Device name 

IMEI: 863071014319393 

IMEI code of the GSM modem 

SN: 000002 

Serial number of the controller 

FW: 0.02 

Controller firmware version 

LITHUANIAN 

SMS text encoding k 

 

Administrators 

are send a test SMS message in a time period specified during the configuration:  

Text 

Meaning 

Description 

 

GV14

 

Object name entered in the field 

Object name 

 

Power:

  

24,5V 

Power supply in voltage 

Signal:

  

90% 

Signal level in percent 

IN1:

  

 
OK 
False

 

IN1 input status: 

 

circuit intact 

 

circuit is broken

 

IN2:

  

 
OK 
False

 

IN2 input status:  

 

circuit intact 

 

circut is broken

 

OUT:

  

 

ON 
OFF

 

Output relay status: 

 

ON 

 

OFF

 

Used Phone: 

 

 

Admin:

  

x/5 

x phone numbers out of 5 possible entered  

User:

 

x/1000 
Fatal ERROR!!! 

x phone numbers out of 1000 possible entered 
Controller is ignoring the phone numbers list due to 
errors  

 

Example of a SMS message response to the SMS inquiry: 

Text 

Meaning 

Description 

GV14 

Object name 

Object name specified during the configuration is displayed in 
the message  

Input1 Event

 

Event in input IN1 
circuit

 

Controller event SMS text specified during the configuration is 
displayed in the message  

 

 

Содержание GV14

Страница 1: ...CONTROLLER GV14 User Manual Draugystes g 17 LT 51229 Kaunas E mail info trikdis lt www trikdis lt...

Страница 2: ...Controller installation 5 Wiring diagrams 7 Configuration using software TrikdisConfig 7 Connecting to a computer 7 Configuration of controller operation 8 User list 9 Administrator list 10 Recording...

Страница 3: ...st c mode Administrator controller output relay contacts may be switched by those whose phone number is on the administrator list Memory of 5 administrator and 1000 user names and their phone numbers...

Страница 4: ...command e g next phone call Memory Up to 5 administrator names and their phone numbers Up to 1000 user names and their phone numbers Inputs 2 IN1 and IN2 Set for NO resistance 10 k or NC resistance 0...

Страница 5: ...SM signal level 30 7 flashes Critical error in the parameters structure 8 flashes Error in the user phone number list structure POWER denotes controller power supply OFF No power supply Green light No...

Страница 6: ...t interruption If these indications are not as such see section Light indication 8 Check if the automatics can be controlled using a phone call call the SIM card number of the controller 9 Send these...

Страница 7: ...rameters are set using computer software TrikdisConfig Software may be found on www trikdis lt Connecting to a computer 1 Connect the controller to the computer USB slot using a USB cable e g USB type...

Страница 8: ...atus Done is displayed after every successful reading or saving action GV14 Product name SN Controller serial number BL Controller firmware boot loader version FW Controller firmware version HW Contro...

Страница 9: ...eration mode a Level relay contacts status is switched to other command status e g other phone call once controller receives a control command b Impulse relay contacts status is switched to the opposi...

Страница 10: ...rst administrator may only be edited and cannot be deleted Controller will not work if not a single administrator phone number is entered and control for the users will be denied Select the encoding l...

Страница 11: ...3 Click Disconnect to disconnect the programmed device Updating the controller firmware Manufacturer may improve the operation of controller GV14 and release a new controller firmware version Every u...

Страница 12: ...3456 password SETAP command APNR1 37068700000 parameters Commands sent in SMS messages No Command Contents Description 1 RESET Resetting controller GV14 E g 123456 RESET 2 INFO Inquiring about the con...

Страница 13: ...events Sending test messages Sending responses to command SMS E g 123456 SETAE APNR1 IN1 ON IN2 ON OUT ON TEST OFF ACK ON 12 SETAN APNR1 Name APNR2 Name APNR3 Name APNR4 Name APNR5 Name Entering of a...

Страница 14: ...trator list will be sent E g 123456 LISTA 20 LISTU An SMS query for a User list in SMS to be sent SMS message containing of a User list will be sent E g 123456 LISTU Automatics control Phone call 1 Ca...

Страница 15: ...GV14 Object name entered in the field Object name Power 24 5V Power supply in voltage Signal 90 Signal level in percent IN1 OK False IN1 input status circuit intact circuit is broken IN2 OK False IN2...

Страница 16: ...ce known to the maintenance specialists Device is disconnected from the electrical network by turning off the automatic fuse Warranty and limitation of liability The manufacturer provides a 24 month w...