Troubleshooting
Properly installed, operated and maintained plants will give many years of trouble-free
service. All plants come fitted with an alarm, which will alert to irregularities in the plant. If
a fault occurs, a buzzer will sound to indicate that there is a problem with the plant. If
required, you can mute the buzzer by holding the middle touch key on the control unit for 5
seconds, until the problem gets fixed. Once fixed, the alarm will reset automatically. All
electrical work shall be carried out by a qualified person.
Symptom
Possible Causes
Solution
The blower will
not start or run
Fuse blew (if applicable)
Replace with a fuse of suitable size
Tripped breaker
Reset breaker
Low line voltage and wet
electrics
An electrician should check the power supply to
the plant
Defective blower
A qualified person must check the blower
Thermal overload protection
triggered by high ambient
temperature
Allow the blower time to cool. The blower will
automatically restart when cooled sufficiently
Blower operates
but delivers no air
Low line voltage or wired
incorrectly
An electrician should check the power supply to
the plant
Filter blocked
Replace filter
Diaphragm damaged/torn (If
applicable)
Replace damaged diaphragm
Defective blower malfunction
A qualified person must check the air blower
Plant fills above
the working
water level
Subsurface disposal plant
clogged
Contact installer to repair subsurface disposal
plant/ percolation area
Stormwater flooding
Redirect stormwater drains. Stormwater must
never enter the plant
Discharge hose/pipe blocked
Find blockage and remove or replace the
damaged hose/pipe