Warning
Tricel shall not be liable for any damage or loss, including consequential loss, caused
by the failure of any plumbing equipment or failure caused by the inclusion of
prohibited material, in the plant.
The manufacturer’s installation, operation and maintenance instructions outlined in this
manual must be followed at all times to ensure the plant operates as designed. Any
variations to these conditions could result in the unit not performing to its full potential,
and the discharge may not meet the required standards.
•
The property owner has a legal responsibility to ensure that the plant does not
cause pollution, a health hazard or nuisance.
•
Desludging is a critical part of the successful operation of the Tricel Vitae and is the
responsibility of the customer. Only competent and approved personnel should carry
out desludging. Desludging must get carried out when required as specified, and the
plant should be regularly inspected to check the depth of sludge in the primary
chamber. If desludging is deemed necessary, carry it out as soon as possible.
•
The electrical connection to the plant requires maintaining for it to function correctly.
This connection ensures that the plant has a continuous air supply and where necessary
the airlifts will operate.
•
The Tricel Vitae is one part of an overall wastewater treatment system which
includes many components (plumbing, ventilation, plant and polishing filter (if
applicable). Each element has to function correctly for the overall system to work
which is the responsibility of the customer.
•
If the installation of the plant is not correctly carried out, flooding, overloading,
electrical shock or floatation may occur. Tricel is not responsible for incorrectly
installed plants.
•
Soakaways drains and the emptying of the primary chamber remains the responsibility
of the customer. Damage to the plant, due to the influx of surface water or the backing
up of soakaways or drains, is not covered by Tricel.
•
To ensure the continuance of the Tricel Vitae’s performance, the customer must take
certain precautions:
o
Do not exceed the design loading of the plant.
o
High volume discharges, such as those from swimming pools and Jacuzzi’s
must never enter the plant.
o
Surface water must not enter the plant.
o
Do not allow large quantities of chemicals to enter the plant including but not
limited to:
Detergent
Water softener
Disinfectants
Strong acids and alkalis, or photographic chemicals
Oil or grease
Petrol or diesel