Essential Characteristic
Performance*
Harmonized Technical
Specification
Nominal Organic Daily Load
0.30 kg/d
Nominal Hydraulic Daily Load 0.75 m
3
/d
COD
94.3%
37.3 mg/l
EN12566-3
BOD
5
98.1%
6.1mg/l
SS
96.2%
13.8 mg/l
NH
4
**
94.2%
2.9mg/l
Electrical Power Consumption
0.65 kWh/d
*Performance results obtained at an average organic daily load of 0.25kg/d and a daily hydraulic
load of 0.9m
3
/d
**Determined at temperatures >12
o
C
Material Performance
Essential Characteristic
Method
Performance
Harmonized
Technical
Specification
Water Tightness
Vacuum Test
Pass
EN12566-3
Crushing Resistance
Pit Test
Pass (also wet conditions)
Durability
Pass
Reaction to Fire
Class E
9.
The performance of the product identified in point 2 conforms with the declared
performance in Point 8.
This declaration of performance is issued under the sole responsibility of the
manufacturer identified in point 4.
Michael Stack Managing Director