26
8
Disposal of treated water
The treated wastewater from the Tricel Vitae should get disposed of as per guidelines from the
planning regulations issued by your local authority.
9
Maintenance
Warning
Any maintenance performed inside the tank represents a confined space. Therefore, the maintenance
person must be suitably trained to work in confined spaces. Sewage and sewage effluent can carry
micro-organisms and gases harmful to human health. Only appropriately trained personnel can carry
out maintenance on the tank. Wear suitable protective equipment including gloves, goggles, etc., at
all times. Always remove contaminated clothing and protective equipment after completion of work.
Wash hands and face prior to eating, drinking or smoking. Please refer to section 1, ‘Health & Safety
precautions.’
•
A certain amount of plant maintenance is required on an on-going basis to ensure that
the plant is working correctly.
•
Ensuring this maintenance is the responsibility of the homeowner.
9.1
Regular maintenance
•
The vents around the base of the blower housing guarantee a fresh supply of air to the
air blower. All vents should be checked to make sure they are not blocked or obscured.
•
Ensure that the plant is running correctly by removing the blower housing and
inspecting the display on the control unit.
•
Inspect the pipework for blockages if necessary. The inlet and outlet should be
inspected and rodded to remove any obstructions if necessary.
9.2
Annual maintenance
•
The Tricel Vitae will require a full service (available from your supplier) once a year to
guarantee the efficiency of the plant gets maintained. Accommodating service
personnel with clear access to the tanks is essential.