5.5
FP4 D424 / FP4 D224
With the FP4 D424 or FP4 D224, each possible outlet is operated individually. One out-
let is supplied with 0.16cm³ lubricant per stroke. The outlets are supplied with lubricant
one after the other.
The FP4 D424 or FP4 D224 allows you to set dosing volume differences from outlets
1.1 and 1.2 to outlets 2.1 and 2.2 by individually controlling the two pump bodies. An
explanation of the different control signals can be found in chapter 8.2.
Number of pump units
2
Number of outlets
4
Differences in dosing volume per
pump unit possible
yes
Maßstab/Scale
Benennung / Title
Material
Name
Datum/Date
Warengruppe
Zeichnungsnr. / Drawing no.
Blatt/Sheet
Gewicht/Weight
Toleranzen / Tolerances: ISO 2768-1 m K
Schaumstoffteile nach DIN 7715 Teil 5 Klasse P2
Dieses Dokument ist Eigentum von: This document is ownership of:
3/3
FlexxPump 402_ZOF
Bearb.
Gepr.
Änd./Index
a
J. Niederg.
J. Niederg.
1:1,5
DIN A4
Maße in mm
VK-Artikel-Nr.
Zust.
Änderung
Datum Name Gepr.
FlexxPump 402
21.11.2017
21.11.2017
Maßstab/Scale
Benennung / Title
Material
Name
Datum/Date
Warengruppe
Zeichnungsnr. / Drawing no.
Blatt/Sheet
Gewicht/Weight
Toleranzen / Tolerances: ISO 2768-1 m K
Schaumstoffteile nach DIN 7715 Teil 5 Klasse P2
Dieses Dokument ist Eigentum von: This document is ownership of:
3/3
FlexxPump 402_ZOF
Bearb.
Gepr.
Änd./Index
a
J. Niederg.
J. Niederg.
1:1,5
DIN A4
Maße in mm
VK-Artikel-Nr.
Zust.
Änderung
Datum Name Gepr.
FlexxPump 402
21.11.2017
21.11.2017