Revision: 0
FlexxPump4 D
User Manual
12
EN-
3.4
Technical data
Housing
Dimensions without housing
111 x 56,5 x 108 (W x H x D)
mm
Dimensions with housing for 250ml cartridge
111 x 165 x 108 (W x H x D)
Dimensions with housing for 400ml cartridge
111 x 200 x 108 (W x H x D)
Weight (without cartridge)
appx.
1190 til 1300 (depeding on version)
g
Mounting options
holes for screw M6
Mounting position
upright
Material
Zinc die-cast / PA 6.6 GF30 / POM
Material outlet
Nickel-plated brass
Operating temperature
-15 ... +60*
°C
Lubricant and hydrauilcs
Cartridge volume
250 / 400
ml
Lubricant characteristics
grease up to NLGI class 2
oil up to 30 000 cSt
Number of outlets
1 / 2 / 3 / 4
Hydraulic connection
via PA-Tube
Number of lubrication points per outlet
up to 4 in conjunction with distributor*
up to 14 in conjunction with aluminum progres-
sive distributor*
max. pressure
70 (-10%/+15%)
bar
Steady state pressure
70
bar
Grease delivery
per stroke
0,16 (-5%)
cm³
Electrics
Display
nonexistant
Operating voltage
24 (+/- 5%)
V
Protection
0,75 (slow blow)
A
Protection class
IP 54
Current consumption
I
max
< 0,3 I
quiescent
< 0,025
A
Further information on electrics can be found in Chap. 8!
* The stated value depends on the specific application and may vary considerably in individual
cases depending on the lubricant used and other conditions.