35
/52
34
Command
Function
Feedback Example
EDIDH[x]B[y].
Input port [y] learns the EDID from output
port [x].
If the EDID data is available and the audio
part supports not only PCM mode, then
force-set it to support PCM mode only. If
the EDID data is not available, then set it
as initialized EDID data.
EDIDH[x]B[y].
EDIDPCM[x].
Set the audio part of input port [x] to PCM
format in EDID database.
EDIDPCM[x].
EDIDG[x].
Get EDID data from output [x] and display
the output port number.
Hexadecimal EDID data and car-
riage return character
EDIDMInit.
Restore the factory default EDID data of
every input.
EDIDMInit.
EDIDM[X]B[Y].
Manually EDID switching. Enable input[Y]
to learn the EDID data of output[X]. If the
EDID data is not available, then set it as
initialized EDID data.
EDIDM[X]B[Y].
EDIDUpgrade
[x].
Upgrade EDID data via the RS232 port.
[x] is the input port, when the value of X is
9, it means to upgrade all input ports.
When the switcher receives the
command, it will show a message to
prompt you to send EDID file (.bin file).
Operations will be cancelled after 10
seconds. Please cut off all connections of
HDBaseT ports.
Please send the
EDID file
EDID/[x]/[y].
Set the EDID data of input port [x] to
built-in EDID No.[y].
[y]=1~4, correspond to the 4 embedded
EDID data
EDID/[x]/[y].