Triax HMX 442 LP4K Скачать руководство пользователя страница 47

47

/52

46 

5. Specifications, For All Triax Matrices, HMX 442LP4K , HMX 663LP4K and HMX 884LP4K 

Video Input

 

Video Output

 

 

 

Input

 

 

 

4, 6 or 8, HDMI

 

 

 

Output

 

2, 3, or 4 HDMI

 

4, 6, or 8 HDBaseT

 

 

 

Input

 

Connector

 

 

 

Female HDMI

 

 

 

Output

 

Connector

 

Female HDMI

 

Female RJ45 (with LED

 

indi-

cators)

 

Input Level

 

T.M.D.S. 2.9V~3.3V

 

Output Level

 

T.M.D.S. 2.9V~3.3V

 

 

 

 

 

Input

 

Impedance

 

 

 

 

 

 

 

100

Ω (

Differential)

 

Output

 

Impedance

 

 

 

100

Ω (

Differential)

 

 

 

HDBaseT Outputs

 

Up to 70m1080P@

60

Hz/ 

40m

4

Kx

2

K

@

30

Hz

 

Video General

 

Gain

 

0 dB

 

Bandwidth

 

10.2 Gbit/s

 

 

 

Video Signal

 

 

 

HDMI (or DVI-D)

 

Maximum

 

Pixel Clock

 

 

 

225MHz

 

Resolution

 

Range

 

 

 

Up to 4Kx2K, 1080P 3D

 

Switching

 

Speed

 

 

 

200ns (Max.)

 

 

 

Max       Pixel

 

Clock

 

 

 

225MHz

 

 

 

EDID Management

 

In-built EDID data and 
manual EDID   
management

 

 

 

HDCP

 

Supports  HDCP  1.4,  auto  detecting  for  HDCP  status&  selectable

 

HDCP status

 

Audio General

 

 

 

Output Signal

 

 

 

Analogue audio

 

Output

 

Connector

 

3-pin pluggable 
terminal block

 

 

 

 

 

PCM Format

 

Distortion:  

0.1% 32

Ω/

70

mW@1KHz, 

  0.1%16

Ω/

105

mW @

1

KHz

 

 

 

Frequency

 

Response

 

 

 

 

 

20Hz~20KHz

 

CMRR

 

>90dB @20Hz ~ 20KHz

 

Control Parts

 

 

 

 

 

 

 

 

 

Control Ports dependant on 

model

 

4, 6, 8 IR OUT (green 

and red)

 

4, 6, 8 IR IN (black)

 

1 IR ALL OUT (black)

 

1 IR ALL IN (black)

 

1 TCP/IP (female RJ45)

 

1 RS232 (9 pin female)

 

 

 

 

 

 

 

 

 

Panel Control

 

 

 

 

 

 

 

 

 

Front panel buttons

 

 

 

4, 6, 8 RS232s (3-pin  

pluggable terminal blocks)

 

 

 

 

 

 

 

IR Control

 

In-built IR sensor, Ex-

tended IR receiver

 

RS232

 

Control

 

 

 

9 pin female

 

TCP/IP Control

 

 

 

Works with In-built web GUI

 

General

 

Power

 

Supply

 

DC 24V 2.5A 

100V~240V AC

 

Power

 

Consumption

 

 48W HMX 442LP4K,  
 80W HMX 663LP4K, 
 103W HMX 884LP4K (full 
load)

 

 

 

Temperature

 

-10 ~ +40

 

Reference

 

Humidity

 

 

 

10% ~ 90%

 

Dimension (W*H*D) 

HMX 442LP4K 

HMX 66sLP4K 

HMX 884LP4K 

  

437 x 44 x 235 mm 

437 x 87.8 x 380 mm 

437 x 87.8 x 380 mm 

  

Weight 

  

2.0kg 

5.3kg 

5.4kg 

Содержание HMX 442 LP4K

Страница 1: ...User Manual triax com in house connectivity User Manual HMX 442 LP4K Matrix Art No 310037 HMX 663 LP4K Matrix Art No 310047 HMX 884 LP4K Matrix Art No 310038...

Страница 2: ...prior written consent of Triax FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful i...

Страница 3: ...the unit to rain moisture or install this product near water Do not put any heavy items on the power cable to prevent damage Do not remove the housing of the device as opening or removing housing may...

Страница 4: ...HMX 663LP4K 310047 10 2 2 1 Front Panel 10 2 2 2 Rear Panel 11 2 3 Product Appearance HMX 884LP4K 310038 12 2 3 1 Front Panel 12 2 3 2 Rear Panel 13 3 System Connection 14 3 1 System Applications 14 3...

Страница 5: ...ontinued 29 4 3 4 RS232 Communication Commands Continued 30 4 3 4 RS232 Communication Commands Continued 31 4 3 4 RS232 Communication Commands HMX 663LP4K HMX 884LP4K 32 39 4 4 RS232 Control Modes 39...

Страница 6: ...riax matrices support EDID management HDCP bi directional RS 232 and IR control Apart from the embedded HDMI audio the Triax matrices provide auxiliary audio inputs Audio source can be selected via RS...

Страница 7: ...ver 1 x Twin High Powered IR Blaster 4 x Plastic feet 4 x Black Screws 1 x IR Remote 3x Interchangeable power cords EU AU NZ and UK 18 x Pluggable Terminal Blocks 1 x Multi lingual User Manual 1 3 3 P...

Страница 8: ...al mode ranging from 1 to 4 Output 1 2 support synchronous local HDMI output EDID Invoking mode press and hold EDID button for 3 seconds to enter mode press buttons 1or 2 these switch to the previous...

Страница 9: ...er on thought to the IR emitter b COAX HDMI de embedded digital audio output c RS232 Serial communications between matrix and the corresponding HDBaseT receiver d HDMI HDMI Type A connectors plug an H...

Страница 10: ...o confirm OUTPUTS buttons EDID Management buttons Normal mode ranging from 1 to 6 Output 1 3 support Synchronous local HDMI output EDID control mode press and hold EDID button for 3 seconds enter this...

Страница 11: ...ls to CAT5e 6 RS232 Serial port for unit control 9 pin female connector enables control of 3rd party device such as a PC IR ALL IN Plug an IR Receiver in to the IR ALL IN 3 5mm jack socket Sends IR co...

Страница 12: ...o confirm OUTPUTS buttons EDID Management buttons Normal mode ranging from 1 to 8 Output 1 3 support Synchronous local HDMI output EDID control mode press and hold EDID button for 3 seconds enter this...

Страница 13: ...to CAT5e 6 RS232 Serial port for unit control 9 pin female connector enables control of 3rd party device such as a PC IR ALL IN Plug an IR Receiver in to the IR ALL IN 3 5mm jack socket Sends IR comm...

Страница 14: ...bs Clubs and Sports Bars 3 2 Usage Precautions 1 System should be installed in a clean environment 2 Ensure that all of the power cords and plugs are not damaged if there are any signs of damage DO NO...

Страница 15: ...ix and far end receivers 7 The Matrix can collect IR signal sent by the included IR remote via its built in IR sensor or through external IR receiver connected to the IR IN IR OUT ALL IR ALL IN port T...

Страница 16: ...output port of the matrix to the pre installed CAT cabling at the receiver location there may a be RJ45 Socket or a direct cable Plug the cable directly in to the receiver If there is a socket install...

Страница 17: ...del When you convert an HDMI input to an output the corresponding IR OUT will be switched synchronously 2 To convert an input to several outputs Operation input output output ENTER Example Switch inpu...

Страница 18: ...ter in sequence and save Example Input 2 learns the EDID information from output 4 EDID ENTER INPUTS 2 4 OUTPUTS All Input ports learn the EDID setting from one specified output sink device The matrix...

Страница 19: ...S To confirm that the programming has been successful the BLUE LED s will flash 3 times at a normal speed if unfortunately the programming was unsuccessful the BLUE LED s will Flash fast 3 times HMX 4...

Страница 20: ...ive you access to the ENQUIRY Mode Use Left and Right direction buttons to navigate the menu Check Output Resolution Use button to check ALL output resolutions separately RESOLUTION OUT 1 1920 x 1080...

Страница 21: ...l IR commands only operate within the actual Zone 3 Menu Button ALL EDID and CLEAR replicate Front functionality 4 Navigation Buttons ENTER to Confirm 5 Output Channels Zone Range 1 8 dependent on mod...

Страница 22: ...ematic below subject to model 4 2 3 IR Matrix Bi directional Control The IR Signal command is received by the HRX 1LP4K Receiver located in the zone modulated and superimposed on to the CAT cabling in...

Страница 23: ...e that you want to control See Schematic below for illustration only To control ALL receivers in the zones a IR emitter needs to connected to the IR ALL IN port on the matrix and an IR Blaster transmi...

Страница 24: ...Matrices enables the end users to control the source equipment whilst in the main viewing area This feature is possible by installing an IR receiver connected to the IR in port on the HRX 1LP4K recei...

Страница 25: ...ect the computer which has the installed RS232 control software Double click the software icon to run the software Here we take the software CommWatch exe as example The software can be downloaded fro...

Страница 26: ...The switching interval is 2 seconds Demo Mode AV 01 01 AV 01 02 AV 01 03 AV 01 04 AV 02 01 Undo To cancel the previous operation Undo Ok Out 01 02 03 04 In 01 01 01 01 Operation Commands x All Transf...

Страница 27: ...the present operation to the preset command Y ranges from 0 to 9 Save To FY Y 0 9 Recall Y Recall the preset command Y Recall From FY Y 0 9 Clear Y Clear the preset command Y Clear FY Y 0 9 PWON Work...

Страница 28: ...and to the cor responding HDBaseT receiver to control far end device Y 5 send this command to all HDBaseT receivers to control all far end devices Y A B C or D Y E F G or H For items c or d send this...

Страница 29: ...it Restore the factory default EDID data of every input EDIDMInit EDIDM X B Y Manually EDID switching Enable input Y to learn the EDID data of output X If the EDID data is not available then set it as...

Страница 30: ...vate carrier native mode 0801 0900 Switch to carrier native mode Carrier native 0901 Switch to force carrier mode Force carrier 0911 Reset to factory default Factory Default 9951 Check the command sen...

Страница 31: ...or 1 Analogue audio Y X Z HDCP management command Y is for input value I or output value O X is the number of the port if the value of X is ALL it means all ports Z is for working status value 1 or 0...

Страница 32: ...gnals from the input channel x to all output channels X To All X 1 8 All Transfer all input signals to the corresponding output channels respectively like 1 1 2 2 All Through All Switch off all the ou...

Страница 33: ...or 1 Analogue audio Y X Z HDCP management command Y is for input value I or output value O X is the number of the port if the value of X is ALL it means all ports Z is for working status value 1 or 0...

Страница 34: ...control all far end devices c Y A B C D E F G or H d Y I J K L M N O or P For items c or d send this command it will be saved to the matrix switcher but taken without action to corresponding HDBaseT...

Страница 35: ...IDMInit Restore the factory default EDID data of every input EDIDMInit EDIDM X B Y Manually EDID switching Enable input Y to learn the EDID data of output X If the EDID data is not available then set...

Страница 36: ...ta of input x x 1 8 0801 Auto HDCP management activate carrier native mode 0801 0900 Switch to carrier native mode Carrier native 0901 Switch to force carrier mode Force carrier 0911 Reset to factory...

Страница 37: ...n PWOFF Port 4 data when PWOFF 9945 Check the command sent by port 5 when PWOFF Port 5 data when PWOFF 9946 Check the command sent by port 6 when PWOFF Port 6 data when PWOFF 9947 Check the command se...

Страница 38: ...HDMI Audio 9971 Check the connection status of the inputs In 1 2 3 4 Connect N Y Y Y In 5 6 7 8 Connect N Y Y Y 9972 Check the connection status of the outputs Out 1 2 3 4 Connect N Y Y Y Out 5 6 7 8...

Страница 39: ...ll the twisted pairs before sending command EDIDUpgrade X 2 In above commands and are symbols for easy reading and do not need to be typed in actual operation 3 Please remember to end the commands wit...

Страница 40: ...Zones 4 4 3 Control 3rd Party Device Locally Connect the 9 pin female RS232 port of the Matrix to the PC by using the RS232 command Y X you are able to control the 3rd party device connected with the...

Страница 41: ...lly from matrix Connect the RS232 3 pin pluggable terminal block port in any zone to PC and connect the controlled RS232 device 3rd party device to the corresponding same zone as PC receiver see below...

Страница 42: ...gle PC Connect the PC to the RJ 45 HDBaseT port on the matrix set the IP address and gateway to the same IP and gateway as the matrix Default 192 168 0 178 Control the Matrix by PC s on a Network LAN...

Страница 43: ...ort 4001 4 5 2 GUI for TCP IP control The Triax series of Matrices come with an on board GUI for convenient TCP IP control The GUI allows the user to interact with the matrix through graphical icons a...

Страница 44: ...possible connection between every input and output Administrators can carry on the connection by clicking on the corresponding button Users display is locked to give minimal access If any changes are...

Страница 45: ...bnet mask and default gateway Note Log in as User access to main interface only 4 5 3 GUI Updates All Triax GUI support online updates visit http 192 168 0 178 100 Type in the Username and password to...

Страница 46: ...file to the PC and double click on the file to start the process When the program is running it will display the update dialogue box shown below Press the Button and choose the upgrade file to be down...

Страница 47: ...tecting for HDCP status selectable HDCP status Audio General Output Signal Analogue audio Output Connector 3 pin pluggable terminal block PCM Format Distortion 0 1 32 70mW 1KHz 0 1 16 105mW 1KHz Frequ...

Страница 48: ...splay doesn t sup port the input resolution Switch for another input source or enable the display to learn the EDID data of the input Cannot control the device via front panel buttons Front panel butt...

Страница 49: ...uthorized dealer for checking Static becomes stronger when connecting the video connectors Bad grounding Check the grounding and make sure it is connected well Cannot control the device by RS232 IR re...

Страница 50: ...User Manual 50 52 Notes for your personal use...

Страница 51: ...Notes for your personal use 51 52...

Страница 52: ...triax com Contact triax com contact 08 2015A SUPPORT P o w e r o v e r E t h e r n e t READY b y p a s s 4x RJ45 RS232 2x 4x...

Отзывы: