User Manual
36
/52
35
Command
Function
Feedback Example
UpgradeIntED ID
[x].
Upgrade one of the 6 embedded EDID
data, x is the serial number for EDID data
1. 1080P 3D 2CH
2. 1080P 3D Multichannel
3. 1080P 2D 2CH
4. 1080P 2D Multichannel
5. 3840x2160 2D (30Hz)
6. 4096x2160 2D (30Hz)
When the switcher gets the command, it will
show a message to send EDID file (.bin
file). Operations will be invalid after
10 seconds.
Please send the
EDID file
GetIntEDID[x].
Return the embedded EDID data ranked x,
[x]=1~6
GetInPortEDI D
[X].
Return the EDID data of input [x], [x]=1~8
%0801.
Auto HDCP management, activate carrier
native mode
%0801.
%0900.
Switch to carrier native mode.
Carrier native
%0901.
Switch to force carrier mode.
Force carrier
%0911.
Reset to factory default.
Factory Default
%9951.
Check the command sent by port 1 when
PWON.
Port 1:data when
PWON
%9952.
Check the command sent by port 2 when
PWON.
Port 2:data when
PWON
%9953.
Check the command sent by port 3 when
PWON.
Port 3:data when
PWON
%9954.
Check the command sent by port 4 when
PWON.
Port 4:data when
PWON
%9955.
Check the command sent by port 5 when
PWON.
Port 5:data when
PWON
%9956.
Check the command sent by port 6 when
PWON.
Port 6:data when
PWON
%9957.
Check the command sent by port 7 when
PWON.
Port 7:data when
PWON