13
Setup Manual - Video Micro Converter
Pin assignment
DMX1–
DMX1+
GND
J1
RJ45-2X4
1
2
3
4
5
6
7
8
Pin
Traxon e:cue
ESTA
1
DMX-
DMX+
2
DMX+
DMX-
3
GND
GND
4
n.c.
n.c.
5
n.c.
n.c.
6
n.c.
n.c.
7
GND
GND
8
GND
GND
General
All settings on the VMC are configured remotely using e:cue Patchelor on a network
enabled computer. Patchelor can be installed from the e:cue Lighting Application
Suite installation CD. Patchelor is also available as a free download from www.ecue.
de.
Network configuration
Factory setting of the IP address of a VMC is: 192.168.123.1
Connecting more than one VMC
In case of having several VMC they need to be configured one at a time, please
do not connect all of them to the network immediately. This is due to the fact that
the devices all come with the same IP address as factory default. If all VMCs are
connected simultaneously an IP address conflict will occur and configuration is not
possible. Instead, connect the VMCs one at a time. Connect the first VMC and as-
sign a new IP address to the device (e. g. 192.168.123.11).
Содержание 160136
Страница 1: ...Video Micro Converter Setup Manual ...
Страница 6: ...6 Setup Manual Video Micro Converter ...
Страница 7: ...7 Setup Manual Video Micro Converter English A high resolution version is available from our website ...
Страница 25: ...25 Setup Manual Video Micro Converter VMC chaining example Video Source ...
Страница 33: ...Deutsch Für eine höher aufgelöste Version besuchen Sie www ecue com download ...
Страница 51: ...51 Setup Manual Video Micro Converter Beispiel VMC Serienschaltung ...
Страница 60: ...60 Setup Manual Video Micro Converter Appendix Anhang ...
Страница 62: ...62 Setup Manual Video Micro Converter Notes Notizen ...
Страница 63: ...63 Setup Manual Video Micro Converter ...