Appendix D Command Quick Reference
This appendix lists the default configuration settings for the Encompass® 4 Reader
and its commands. Commands are listed both numerically and alphabetically.
Command Syntax
The command numbers consist of from 2 to 4 hex digits. The letters N or S may follow a command number.
The letter N indicates that part of the command number is variable. The letter S indicates the requirement for
an alphanumeric data string that is to be included immediately following the command number. Hex digits
(0–9, A–F) in either uppercase or lowercase characters may be used in data strings and for hex digits A–F.
For more information see
“Chapter 5 General Software Information” on page 5–67.
lists factory default settings.
lists, in numerical order, all of the commands available to
users.
lists the same commands by command name.
Factory Default Settings
lists the factory default settings for the Encompass 4 Reader.
Table 55 Encompass 4 Reader Default Configuration Settings
Parameter
Setting
Command
Switch to data mode
Data
00
Baud rate
9600
1005
Stop bits
1
1010
Disable parity
None
1020
Time and date appended
Enabled
302
No auxiliary information appended
Disabled
310
EAC page append
Disabled
320
Unique ID code criteria
Separation of 1 ID
4100
Valid ID code criteria
Acquisition of 1 ID
4200
Uniqueness timeout
2 minutes
441
Wiegand mode
Disabled
450
Tag translation mode
Disabled
452
Multi-tag sort
Disabled
454
eGo Plus tag initialization during multi-tag
sort
Enabled
456
Second alternate group select
Disabled
458
Appendix D Command Quick Reference
TransCore Proprietary
D–1
Содержание encompass 4