Chapter 8 Configuring the Encompass 4 Reader
This chapter provides instructions for configuring the Encompass® 4 Reader,
including factory configuration parameter defaults and instructions for using
terminal emulation software to check and change the Encompass 4 Reader factory
configuration defaults.
Configuring the Reader
After installing the Encompass 4 Reader, you need to configure its operating parameters. Terminal settings
should be initially set at 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control.
General Configuration Labeling
Each Encompass 4 Reader and its shipping carton are labeled to indicate the unit’s ordering configuration.
contains explanations of the Encompass 4 Reader label fields.
Table 42 Encompass 4 Reader Configuration Label Fields
Field
Description
1st
TransCore reader designator
2nd
Model number
40 = 915 MHz frequency band
3rd
Interface
xy where
x = 0 (integrated antenna); x = 1 (external antenna)
y = 2 (RS–232 and Wiegand); y = 4 (RS–422 and
Wiegand)
4th
0nn where
nn = tag protocol(s). Protocol designators are as follows:
001 = Super eGo® (SeGo) protocol
002 = ATA/SeGo protocols 003 = eGo/SeGo protocols
004 = SeGo/Inter-Agency Group (IAG) protocols 008 =
ATA protocol
009 = eGo/ATA protocols 010 = ATA/IAG protocols 019 =
IAG protocol
Chapter 8 Configuring the Encompass 4 Reader
TransCore Proprietary
8–133