Table 39 Timeout Period Values
Command
Timeout (ms)
6930
0 (always expired)
6931
4
6932
8
6933
12
6934
20
6935
24
6936
32
6937
48
6938
60
6939
92
693A
152
693B
300
693C
452
693D
600
693E
752
693F
Infinite (never expires, factory default)
Reader response:
Done or Error
The reader returns an
Error
message if a valid hexadecimal digit is not substituted for
N
in command
#693N
.
694N Select Input Inversion Option
Command
#694N
enables or disables input inversion. When inversion is enabled, an open circuit input
is interpreted as a closed circuit, and a closed circuit input is interpreted as an open circuit. This feature
allows greater flexibility in the attachment of external equipment to the reader inputs. For example, some
proximity sensors indicate presence with an open circuit. In this instance, command
#6941
can enable
input inversion so that an open circuit input indicates a presence. The values for
N
represent the two