76
505
Start
(START)
Value:
Digital input (DIGITAL INPUT)
[0]
Serial communication (SERIAL PORT)
[1]
Logic and (LOGIC AND)
[2]
★
Logic or (LOGIC OR)
[3]
Function:
See the functional description under parameter 503,
Coasting Stop.
Description of choice:
The table below shows when the motor has stopped and gives the
situations in which the drive has a start command when
Digital input
,
Serial communication
,
Logic and
or
Logic or
has been selected.
504
DC Brake
(DC BRAKE)
Value:
Digital input (DIGITAL INPUT)
[0]
Serial communication (SERIAL PORT)
[1]
Logic and (LOGIC AND)
[2]
★
Logic or (LOGIC OR)
[3]
Function:
See the functional description under parameter 503,
Coasting Stop.
Description of choice:
The table below shows when the motor is running and is DC-braking
when
Digital input
,
Serial communication
,
Logic and
or
Logic or
has
been selected.
NOTE
DC braking inverse,
through terminals 19 and
27, and bit 03 of the control word, is active when
logic 0 is selected.
Digital Input
Serial Communication
Term.
Serial
Term.
Serial
19/27
Comm. Function
19/27
Comm.
Function
0
0
DC brake
0
0
DC brake
0
1
DC brake
0
1
Motor run
1
0
Motor run
1
0
DC brake
1
1
Motor run
1
1
Motor run
Logic and
Logic or
Term.
Serial
Term.
Serial
19/27
Comm. Function
19/27
Comm.
Function
0
0
DC brake
0
0
DC brake
0
1
Motor run
0
1
DC brake
1
0
Motor run
1
0
DC brake
1
1
Motor run
1
1
Motor run
Digital Input
Serial Communication
Serial
Serial
Term. 18 Comm. Function Term. 18 Comm.
Function
0
0
Stop
0
0
Stop
0
1
Stop
0
1
Start
1
0
Start
1
0
Stop
1
1
Start
1
1
Stop
Logic and
Logic or
Serial
Serial
Term. 18 Comm. Function Term. 18 Comm.
Function
0
0
Stop
0
0
Stop
0
1
Stop
0
1
Start
1
0
Stop
1
0
Start
1
1
Start
1
1
Start
✭
I