4
General Information
Model Number Description
All products are identified by a multiple character model
number listed on the unit nameplate. An explanation of the
alphanumeric identification code is provided below. Its use
can define the unit's specific components, type of applica-
tion, i.e. CV or VAV, for a particular unit.
When ordering replacement parts or requesting service, be
sure to refer to the specific model number, serial number,
and DL number (if applicable) stamped on the unit name-
plate.
Sam ple Model No.: S X H F - C20 4 0 A 1 0 A 1 5 B 1 D 0 1 A,R,L,etc.
Digit No.: 1 2 3 4 5,6,7 8 9 10 11 12 13 14 15 16 17 18 19 20 21+
Digit 1 - Unit Type
Digit 10 - Design Sequence
Digit 17 - System Control
S = Self-Contained
3 = Dis connect Redes ign
1 = CV Control (Zone Control)
Note: Sequence may be any letter
2 = VAV-(S/A Temp Control
Digit 2 - Unit Function
A thru Z, or an y digit 1 thru 9.
without Inlet Guide Vanes)
A = DX Cooling, No Heat
3 = VAV-(S/A Temp Control
E = DX Cooling, Electric Heat
Digit 11 - Exhaust Option
with Inlet Guide Vanes)
F = DX Cooling, Natural Gas Heat
0 = None
4 = Space Press ure Control with Exhaus t VFD
L = DX Cooling, Hot Water Heat
1 = Barometric
without By pass
S = DX Cooling, Steam Heat
2 = 100% - 1.5 HP*
5 = Space Press ure Control with Exhaus t VFD
X = DX Cooling, Extended Cas ings
3 = 100% - 3 HP*
and Bypas s
# = DX Cooling, Propane Gas Heat
4 = 100% - 5 HP*
6 = VAV Supply Air Temperature Control
5 = 100% - 7.5 HP*
with VFD w/o Bypas s
Digit 3 - Unit Airflow
6 = 100% - 10 HP*
7 = VAV Supply Air Temperature Control
H = Single-Zone
7 = 100% - 15 HP*
with VFD and Bypass
8 = 100% - 20 HP*
8 = Supply and Exhaus t Fan with VFD
Digit 4 - Development Sequence
A = 50% - 1.5 HP
without Bypass
F
= Six th B = 50% - 3 HP 9 = Supply and Exhaus t Fan with VFD
C = 50% - 5 HP
and By pas s
Digits 5, 6, 7 - Nominal Capacity
D = 50% - 7.5 HP
C20 = 20 Tons C55 = 55 Tons
E = 100% - 1.5 HP**
Digit 18 - Accessory Panel
C25 = 25 Tons C60 = 60 Tons
F = 100% - 3 HP**
0 = None
C30 = 30 Tons C70 = 70 Tons G = 100% - 5 HP** A = BAYSENS008*
C40 = 40 Tons C75 = 75 Tons
H = 100% - 7.5 HP**
B = BAYSENS010*
C50 = 50 Tons
J = 100% - 10 HP**
C = BAYSENS013*
K = 100% - 15 HP**
D = BAYSENS014*
Digit 8 - Power Supply
L = 100% - 20 HP**
E = BAYSENS019*
4 = 460/60/3 XL
# = 50% w/ Statitrac
F = BAYSENS020*
5 = 575/60/3 XL
* w/Statitrac
G = BAYSENS021*
E = 200/60/3 XL
** w/o Statitrac (CV only )
F = 230/60/3 XL
Digit 19 - Ambient Control
Note: SEHF units (unit with
Digit 12 - Exhaust Fan Drive
0 = Standard
electric heat) utiliz ing 208V or
0 = None 8 = 800 PRM
1 = 0 Degree Fahrenheit
230V require dual power source.
4 = 400 RPM 9 = 900 RPM
5 = 500 RPM A = 1000 RPM
Digit 20 - Agency Approval
Digit 9 - Heating Capacity
6 = 600 RPM B = 1100 RPM
0 = None (UL Gas Heater, s ee note)
7 = 700 RPM
1 = UL
Note: When the second digit
2 = CSA
calls for "F" (Gas Heat), the
Digit 13 - Filter Type
Note: Includes UL clsssified gas heating
follow ing values apply:
A = Throwaway
section only when second digit of
Additionally, please note G and
B = Cleanable Wire Mes h
Model No. is a "F".
M available ONLY on 50 Ton
C = High-Efficienc y Throwaway
models and above.
D = Bag with Prefilters
Digits 21 - 38 - Miscellaneous
H = High Heat - 2 Stage
E = Cartridge with Prefilters
21 A = Unit Disc onnec t Switc h
L = Low Heat - 2 Stage
F = No Filters (T/A Rack Only)
22 B = Hot Gas Bypas s
0 = No Heat
G = No Filters (Bag/Cart. Rack O nly)
23 C = Economizer Control w/Comparative
J = Limited Modulating High Heat
Enthalpy
G = Limited Modulating Low Heat
Digit 14 - Supply Fan Horsepower
23 Z = Economizer Control w/Reference
P = Full Modulating High Heat
1 = 3.0 HP 6 = 20.0 HP
Enthalpy
M = Full Modulating Low Heat
2 = 5.0 HP 7 = 25.0 HP
23 W = Economiz er Control w/Dry Bulb
Note: When the second digit
3 = 7.5 HP 8 = 30.0 HP
23 O = None W/O Economiz er
calls for "E" (electric heat), the
4 = 10.0 HP 9 = 40.0 HP
1
24 E = Low Leak Fres h Air Dampers
follow ing values apply:
5 = 15.0 HP
25 F = High Duct Temperature Thermos tat
D = 30 KW R = 130 KW
26 G = High Capacity Ev aporator Coil
H = 50 KW U = 150 KW
Digit 15 - Supply Fan Drive
27 H = Copper Fins (Cond. only)
L = 70 KW V = 170 KW
5 = 500 RPM B = 1100 RPM
28 K = Generic B.A.S. Module
N = 90 KW W = 190 KW
6 = 600 RPM C = 1200 RPM
29 L = High-Efficiency Motors (Supply & Exhaust)
Q = 110 KW
7 = 700 RPM D = 1300 RPM
30 M = Remote Human Interfac e
Note: When the second digit calls
8 = 800 RPM E = 1400 RPM
31 N = Ventilation Override Module
"L" (Hot Water) or "S" (Steam)
9 = 900 RPM F = 1500 RPM
32 R = Extended Grease Lines
Heat, one of the following valve
A = 1000 RPM G = 1600 RPM
33 T = Acc es s Doors
size values must be in Digit 9:
34 V = Interproc ess or Communic ations Bridge
High Heat Coil: 1 = 50", 2 = .75",
Digit 16 - Fresh Air Section
35 0 = No c ommunication module
3 = 1", 4 = 1.25", 5 = 1.5", 6 = 2".
A = No Fresh Air
35 Y = Trane Communic ation Interfac e Module
Low Heat Coil: A = .50", B = .75",
B = 0-25% Manual
35 7 = LonTalk® Communication Interface Module
C = 1", D = 1.25", E = 1.5", F = 2".
D = 0-100% Ec onomizer
36 8 = Spring Is olators
37 6 = Factory-Powered 15A G FI Conv enienc e
O utlet
38 0 = None
1. Available as standard 460 volt only for 70 and 75 ton models.
Содержание INTELLIPAK RT-SVX10C-EN
Страница 16: ...15 Figure 3 1 Minimum Operation and Service Clearances for Single Multiple Unit Installation...
Страница 17: ...16 Figure 3 2A SAHF Cooling Only Units 20 thru 75 Ton...
Страница 19: ...18 Figure 3 2B SEHF SFHF SLHF SSHF SXHF Units 20 thru 75 Ton...
Страница 21: ...20 Figure 3 2C S_HG Cooling Heating Units 90 through 130 Ton...
Страница 25: ...24 Figure 3 4 Typical Unit Rigging Figure 3 5 Unit Base Roof Curb Section...
Страница 38: ...37 Figure 3 13 Steam Coil Piping 20 through 30 Ton Units Steam Coil Piping 40 through 130 Ton Units...
Страница 41: ...40 Figure 3 14 Continued Typical Field Power Wiring 90 thru 130 Ton Table 3 6 Customer Connection Wire Range...
Страница 52: ...51 Field Connection Diagram Notes for 20 through 130 Ton CV or VAV Applications...
Страница 86: ...84 Figure 4 6 Compressor Locations...
Страница 103: ...101 Service Maintenance Continued Table 5 3 Unit Internal Fuse Replacement Data VFD Factory Settings...
Страница 117: ...115...
Страница 118: ...116...