19
Installation (Continued)
Table 3-2A
Unit Dimensional Data
Unit
Dimensions
Size
A
B
C
D
E
F
G
H
J
20 & 25 Ton
24'-1 3/8"
5'-3 1/8"
7'-6 1/2" 5'-8 15/16" 3'-9 5/16"
13'-3"
1"
7'
1'-3 1/2"
30 Ton
24'-1 3/8"
5'-8 5/8"
7'-6 1/2"
6'-2 3/8"
4'-9 5/16"
13'-3"
1"
7'
1'-3 1/2"
40 Ton
30'-2 1/2"
6'-1 5/8"
7'-6 1/2"
6'-7 3/8"
5'-9 5/16" 15'-11 1/8"
1"
8'
2'-5"
50 & 55 Ton 32'-10 1/2" 5'-3 1/8"
7'-6 1/2"
5'-8 7/8"
6'-9 5/16" 15'-11 1/8"
1"
8'
2'-5"
60 Ton
30'-2 1/2"
6'-1 5/8"
9'-8"
6'-7 3/8"
5'-9 5/16" 15'-11 1/8"
1"
8'
2'-5"
70 & 75 Ton
30'-2 1/2"
6'-1 5/8"
9'-8"
6'-7 3/8"
5'-9 5/16" 15'-11 1/8"
1"
8'
1'-4"
Dimensions
K
L
M
N
O
16'-7"
16'-6"
8 1/8"
6 1/4"
9"
16'-7"
16'-6"
8 1/8"
6 1/4"
9"
19'-7"
See Note
8 1/8"
6 1/4"
9"
19'-7"
See Note
8 1/8"
6 1/4"
9"
19'-7"
See Note
8 1/8"
6 1/4"
9"
Note: 19'-6" for SFHF "Low Heat" units or 20'-3" for SFHF "High Heat" units.
Table 3-2B
Unit Base Dimensional Data
Unit
Dimensions
Size
A
B
C
D
E
F
G
H
20 - 30 Ton 16'-3 3/16" 2'-2 1/2" 5 13/16"
5'-7"
3'-4 3/8" 5 13/16" 6'-6 15/16" 15'-5 5/16"
40 - 55 Ton 19'-10 5/16"
2'-5"
7 1/16"
5'-7"
3'-4 3/8" 5 13/16" 7'-8 3/16" 18'-11 11/16"
60 Ton
19'-10 5/16"
2'-5"
6 1/16"
Note 1 4'-5 3/8" 5 13/16" 7'-8 3/16" 18'-11 11/16"
70 - 75 Ton 19'-10 5/16"
2'-5"
6 1/16"
Note 1 4'-5 3/8" 5 13/16" 7'-8 3/16" 18'-11 11/16"
Unit
Dimensions
Size
J
K
L
20 - 30 Ton 16'-9 3/4" 8 13/16"
9 1/16"
40 - 55 Ton 20'-1 3/4"
8 3/16"
9 1/16"
60 Ton
20'-1 3/4"
8 3/16"
9 1/16"
70 - 75 Ton 20'-1 3/4"
8 3/16"
9 1/16"
Note:
1. 5'-5 15/16" for SEHF units or 7'-8 1/2" for SFHF, SLHF, SSHF, SXHF units.
Table 3-2C
Electrical Entrance Data
Unit
Dimensions
Size
F
G
H
J
K
L
M
N
20, 25, & 30 8 7/32" 6 31/32" 15 21/32" 13 21/32" 9 17/32"
8 1/2"
18 1/16" 19 9/16"
50 & 55 Ton
40, 60, 70
8 3/4"
7 3/4"
17 7/8"
15 7/8"
9 29/32" 10 1/16" 20 13/32" 22 5/32"
& 75 Ton
Table 3-2D
CPVC Dimensional Data
Unit Size
Furnace
Dimensions (Note)
Unit Size
Furnace
Dimensions (Note)
Size/MBH
Length
Height
Size/MBH
Length
Height
20 & 25 Ton
Low = 235
195-5/32"
9-5/32"
50 - 75 Ton
Low = 500
240-1/8"
9-5/32"
High = 500
195-5/32"
9-5/32"
High = 850
231-1/8"
9-5/32"
30 Ton
Low = 350
195-5/32"
9-5/32"
90 -130 Ton
1000
267-3/16"
10-11/32"
High = 500
195-5/32"
9-5/32"
Note: The length dimension is from the exhaust
40 Ton
Low = 350
240-1/8"
9-5/32"
end of the unit. The height dimension is
High = 850
231-1/8"
9-5/32"
from the bottom of the unit base rail.
Содержание INTELLIPAK RT-SVX10C-EN
Страница 16: ...15 Figure 3 1 Minimum Operation and Service Clearances for Single Multiple Unit Installation...
Страница 17: ...16 Figure 3 2A SAHF Cooling Only Units 20 thru 75 Ton...
Страница 19: ...18 Figure 3 2B SEHF SFHF SLHF SSHF SXHF Units 20 thru 75 Ton...
Страница 21: ...20 Figure 3 2C S_HG Cooling Heating Units 90 through 130 Ton...
Страница 25: ...24 Figure 3 4 Typical Unit Rigging Figure 3 5 Unit Base Roof Curb Section...
Страница 38: ...37 Figure 3 13 Steam Coil Piping 20 through 30 Ton Units Steam Coil Piping 40 through 130 Ton Units...
Страница 41: ...40 Figure 3 14 Continued Typical Field Power Wiring 90 thru 130 Ton Table 3 6 Customer Connection Wire Range...
Страница 52: ...51 Field Connection Diagram Notes for 20 through 130 Ton CV or VAV Applications...
Страница 86: ...84 Figure 4 6 Compressor Locations...
Страница 103: ...101 Service Maintenance Continued Table 5 3 Unit Internal Fuse Replacement Data VFD Factory Settings...
Страница 117: ...115...
Страница 118: ...116...