102
Table 5-4
Filter Data
Panel-Type Filters
Bag-Type Filters
Cartridge Filters
Panel-Type Prefilters
Unit Model
(Note 1)
(Note 2)
(box-type) (Note 2)
(Note 3)
Qty
Size of each
Qty.
Size of each
Qty.
Size of each
Qty.
Size of each
S_HF-C20 &
12
20 X 20 X 2
4
12 X 24 X 19
4
12 X 24 X 12
4
12 X 24 X 2
C25
3
24 X 24 X 19
3
24 X 24 X 12
3
24 X 24 X 2
S_HF-C30
16
20 X 20 X 2
2
12 X 24 X 19
2
12 X 24 X 12
2
12 X 24 X 2
6
24 X 24 X 19
6
24 X 24 X 12
6
24 X 24 X 2
S_HF-C40
16
20 X 25 X 2
5
12 X 24 X 19
5
12 X 24 X 12
5
12 X 24 X 2
6
24 X 24 X 19
6
24 X 24 X 12
6
24 X 24 X 2
S_HF-C50 &
20
20 X 25 X 2
3
12 X 24 X 19
3
12 X 24 X 12
3
12 X 24 X 2
C55
9
24 X 24 X 19
9
24 X 24 X 12
9
24 X 24 X 2
S_HF-C60,
35
16 X 20 X 2
6
12 X 24 X 19
6
12 X 24 X 12
6
12 X 24 X 2
C70 & C75
8
24 X 24 X 19
8
24 X 24 X 12
8
24 X 24 X 2
S_HG-C90 &
25
24 X 24 X 2
3
12 X 24 X 19
3
12 X 24 X 12
3
20 X 24 X 2
S_HG-D11
15
24 X 24 X 19
15
24 X 24 X 12
15
24 X 24 X 2
S_HG-D12 &
25
24 X 24 X 2
3
12 X 24 X 19
3
12 X 24 X 12
3
20 X 24 X 2
S_HG-D13
15
24 X 24 X 19
15
24 X 24 X 12
15
24 X 24 X 2
Notes:
1. Dimensions shown for “Panel-Type Filters”apply to “Throw away”, “Cleanable Wire Mesh”,
and “High Efficiency Throw away” Filters.
2. S_HF units ordered with “Bag-Type Filters” or “Cartridge Filters” (box-type) include a bank
of “Panel-Type Prefilters”.
3. The same “Panel-Type Prefilters” are used with “Bag-Type” and “Cartridge (box-type)” filters.
Table 5-5
"Wet Heat" Coil Fin Data
Total Coil
Fins
Fins
Coil
Coil
Face Area
per
per
Model
Type
Rows
(sq.ft.)
Foot
Foot
SLHF-C20,
WC
C25 & C30
Prima Flo
2
13.75
80
110
(hot water)
SLHF-C40,
WC
C50 & C55
Prima Flo
2
19.25
80
110
(hot water)
SLHF-C60,
WC
C70 & C75
Prima Flo
2
26.25
80
110
(hot water)
SLHG-C90,
WC
D11, D12
Prima Flo
2
17.5 (2)
80
110
& D13
(hot water)
SSHF-C20,
NS
1
13.75
42
96
C25 & C30
(steam)
SSHF-C40,
NS
1
13.75 (1)
42
96
C50 & C55
(steam)
5.5 (1)
SSHF-C60,
NS
1
18.75 (1)
42
72
C70 & C75
(steam)
7.5 (1)
SLHG-C90,
NS
1
17.5 (2)
52
96
D11, D12
(steam)
& D13
Note: To determine unit heating capacity (i.e., “low heat” or “high heat”),
see Digit 9 of the model number stamped on the unit nameplate.
Service & Maintenance (Continued)
Содержание INTELLIPAK RT-SVX10C-EN
Страница 16: ...15 Figure 3 1 Minimum Operation and Service Clearances for Single Multiple Unit Installation...
Страница 17: ...16 Figure 3 2A SAHF Cooling Only Units 20 thru 75 Ton...
Страница 19: ...18 Figure 3 2B SEHF SFHF SLHF SSHF SXHF Units 20 thru 75 Ton...
Страница 21: ...20 Figure 3 2C S_HG Cooling Heating Units 90 through 130 Ton...
Страница 25: ...24 Figure 3 4 Typical Unit Rigging Figure 3 5 Unit Base Roof Curb Section...
Страница 38: ...37 Figure 3 13 Steam Coil Piping 20 through 30 Ton Units Steam Coil Piping 40 through 130 Ton Units...
Страница 41: ...40 Figure 3 14 Continued Typical Field Power Wiring 90 thru 130 Ton Table 3 6 Customer Connection Wire Range...
Страница 52: ...51 Field Connection Diagram Notes for 20 through 130 Ton CV or VAV Applications...
Страница 86: ...84 Figure 4 6 Compressor Locations...
Страница 103: ...101 Service Maintenance Continued Table 5 3 Unit Internal Fuse Replacement Data VFD Factory Settings...
Страница 117: ...115...
Страница 118: ...116...