User Manual
THIS DOCUMENT IS UNCONTROLLED WHEN PRINTED
Page
14
of
34
STEP 3
–
Remote operation.
•
Push the button on the remote controller.
•
Push the button to run through each respective operation (up/down).
•
Ensure both remotes are tested on a daily basis.
4.6.
Automatic operation
The product can be operated using an automatic cycle which is pre-programmed, this is generally
used as the default for field operations.
STEP 1
–
Automatic operation.
•
Ensure the product is turned off prior to selecting the relevant mode(s).
•
Switch AO (auto open) to commence the automatic operation with the boom up/open.
•
Switch AC (auto close) to commence the automatic operation with the boom down/closed.
•
For simultaneous operations, ensure the relevant switches are pushed up.
4.7.
Activating switch functions and accessories
In order for any of switch functions and subsequent attachments to work, the product must be
turned off, the relevant switch activated and the product turned on. The self-testing cycle will
register the switch and connected accessory during this process.
4.8.
Overriding cycles
Cycles can be overridden using the manual switch or remote. Press the red button on the control
panel or the button on the remote control to override the current cycle.
4.9.
Product security
To ensure that the product is not tampered with while in operation, ensure:
•
All access panels are secured/locked and keys removed.
•
Keep keys and remote controls on your person.
•
Regularly monitor the product, check for tampering and report any damage.
WARNING
•
Check for overhead hazards and ensure the area under the boom is clear prior to testing.
•
Ensure the product is turn off prior to engaging different modes and switches.
•
If any of the checks or cycles fail, do not use the product.
•
Refer to the trouble shooting section, if that fails contact your distributor for assistance.
•
It is recommended that safety sensors are used for all automatic boom operations.