User Manual
THIS DOCUMENT IS UNCONTROLLED WHEN PRINTED
Page
11
of
34
4.
Operation
4.1.
Control panel and switch modes
The control panel contains the primary switches that control the product and accessories. The
switches identify the different modes of operation available to the product.
The switch modes are captured in the below table:
Switch
Term
Details
AC
Auto Close
Automatic cycle starts with boom down.
AO
Auto Open
Automatic cycle starts with boom up.
SS
Safety Sensor
Sensor prevents boom from coming down if broken.
DL
Disable LEDs
Disables the LED warning lights on the front panel.
DB
Disable Boom
Disables the boom arm.
To turn ON a mode, switch upwards. To turn OFF a mode, switch downwards. Multiple modes may be activated
simultaneously when using accessories, ensure they are switched on.
STEP 1
–
Accessing the control panel.
•
Unlock the control panel using the key provided.
•
Align the key etching with the red dot on the lock and turn the key.
STEP 2
–
Select the mode.
•
Standard manual boom operation is enabled when all mode switches are off (down).
•
Ensure the product is turned off prior to selecting the relevant mode(s).
•
Identify the mode(s) relevant to the operation and press the switch up to turn on.
•
Ensure the relevant accessories are plugged in and connected.
•
If multiple modes are going to be in operation, ensure they are all switched on.
STEP 3
–
Securing the control panel.
•
Once the mode(s) have been selected and product tested, lock the control panel and
remove the key.