5
GB
1
2
3
a
b
c
d
e
Cat B
DC
avg
none DC
avg
none
DC
avg
low DC
avg
medium DC
avg
low DC
avg
medium DC
avg
high
Cat 1
Cat 2
Cat 2
Cat 3
Cat 3
Cat 4
Key
PL
performance level
1 MTTF
D
of each channel = low
2 MTTF
D
of each channel = medieum
3 MTTF
D
of each channel = high
Figure 5 - Relationship between categories, the DCavg, the le MTTF
D
of each channel and PL.
NOTE
B
10D
canbebetteriftheinductiveloadisreduced.
Forfurherinformation,contactTractel
®
.
DANGER
The integrator must take care that the inductive
loadcoulddamagethedeviceandcouldreducethe
electricallifeduration.Westronglyrecommendnot
toexceedanapparentpowerof80VAwith48Vac
voltagemax.
Factorycalibrationoption:foreachthreshold,indicatewireropedforceonstrand.
3.4. Designation, characteristics and outline dimensions
Type
Code
Wire rope
diameter
mm
Capacity
daN
Width
mm
Length
mm
Thickness
mm
Weight
kg
HF31/1/A2
87768
From
5 to 16
From
200 to 3200
86
150
40
0.84
3.5. Applicable standard: 2006/42/CE / EN ISO 13849