![Track Wrench BlueTorq Auditor Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/track-wrench/bluetorq-auditor/bluetorq-auditor_operating-manual_1147145023.webp)
23
WWW.
TRACKWRENCH.COM
4.3.8.
Results Table
Figure 4.3.8.: Results Table
The results table is only populated when torque results are uploaded to
the PCFE. Results that are highlighted green indicate that the torque or
angle measurement was “good”, i.e. the torque or angle applied was
within the pre-configured tolerances. Conversely, results highlighted
red indicate that the torque or angle measurement was “bad”, i.e. the
torque or angle applied fell outside the pre-configured tolerances.
4.3.9.
SPC
Graph
To access SPC graphic functionality there must be at least ten results
uploaded to the PCFE. Figure 10 shows the control panel of the SPC
Graph feature.
Figure 4.3.9.A: SPC Graph Control Screen
1.
Date Range
: This setting is used to select the range of results
that are to be graphed. The minimum and maximum values
default to the oldest and latest results respectively. To change
these dates, press the button above the appropriate date.
These select the desired date from the calendar.
2.
Preset Select
: Select the preset you wish to graph.
Note:
To
graph a preset, at least 10 measurements for the individual
preset must be reset.