![Track Wrench BlueTorq Auditor Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/track-wrench/bluetorq-auditor/bluetorq-auditor_operating-manual_1147145010.webp)
Figure 3.6:
Preset Mode Graph
10
Operating Manual
BlueTorq-Series
WWW.
TRACKWRENCH.COM
3.6. Preset Mode (All Series)
In Preset mode, the maximum torque reading will remain on the OLED
display when the load is removed as long as the torque loaded is
above the 10% of maximum capacity threshold.
Depending on the maximum torque recorded, there are various
warning signals activated:
• Passing Minimum Value – The green LED on the keypad will
flash, and the buzzer will sound intermittently, while the OLED
display will change to orange.
• Passing Nominal Value – The green LED on the keypad will
turn on, and the buzzer will sound continuously, while the
OLED display will change to green.
• Passing Maximum Value – The red LED will flash continuously,
and the buzzer will sound continuously, while the OLED
display will change to red.
1. Press to scroll to Preset mode.
2. Press to enter Preset mode.
3. Press to select your preferred preset number i.e. 1 to 99
(Pro Series Wrenches have 1 configurable preset,
Super & Auditor Series have 99).
4. Press to operate within this preset parameter.
5. Press to store the applied torque if required.
3.7. Set
Mode
This mode allows the user to set limits for the torque or angle,
applied. The operator can choose to set values by either percentage
or numerical tolerance. During operation the OLED display will be
green when approaching the preset tolerance and will change to red
if exceeded.