![Track Wrench BlueTorq Auditor Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/track-wrench/bluetorq-auditor/bluetorq-auditor_operating-manual_1147145013.webp)
Figure 3.8:
Just Angle Mode
Figure 3.9:
Just Move Mode
13
WWW.
TRACKWRENCH.COM
3.8. Just Angle Mode
(Auditor Series only Mode)
In Just Angle Mode, the maximum torque reading will remain on
the OLED display when the load is removed as long as the torque
loaded is above the 10% of maximum capacity threshold. The angle
turned from 5% of the tool span until maximum torque reading is also
displayed. The user has the option to store the reading in memory. If
storage of the reading is not required, the user may continue to the
next measuring task.
1. Press to scroll to Just Angle mode.
2. Press to enter in Just Angle mode.
3. Press to store the peak torque and peak angle values if
desired once a torque has been applied. If storage is not
required, apply a new load to capture the next result.
3.9. Just
Move
Mode
(Auditor Series only Mode)
In Just Move Mode, the torque recorded after a pre-defined number
of degrees (Defined in Set Mode) will remain on the OLED display
when the load is removed, as long as the torque loaded is above the
10% of maximum capacity threshold. The final torque and final angle
measurements will also be displayed. The user has the option to store
the reading in memory. If storage of the reading is not required, the
user may continue to the next measuring task.
1. Press to scroll to Just Move mode.
2. Press to enter Just Move mode.
3. Press to store the Just Move torque along with the final
peak torque and peak angle values. If storage is not required,