Parameter definition / CRC calculation
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 90 of 159
TR - ECE - TI - DGB - 0292 - 01
09/20/2016
3.1.1 CRC calculation via iParameters
The preset standard values are used for the following example of a CRC calculation.
These can be loaded in the
TR_iParameter
program using an XML template file. If
different values are required, the standard values can be overwritten by double-
clicking on the relevant entry. The modified parameters can be saved as a complete
parameter set or opened again as a template.
Start
TR_iParameter
by means of the start file "TR_iParameter.exe", then via
the menu
File -> Open XML template...
open the template file supplied
with the measuring system (in this example: CDx75M_EPN_002.xml).