Extending the Safety Program
– Application Examples
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 146 of 159
TR - ECE - TI - DGB - 0292 - 01
09/20/2016
5.2.3 Block creation
In order to create the manufacturer error block, first a new function block must be
created with the name
TR_Manufacturer_Error
. To do this, go to
Project
tree
and in the directory tree select the entry
CD_75_-EPN_PROFIsafe ->
PLC_1 [CPU 1511F-1 PN] -> Program blocks -> Add new block
by
double-clicking with the left mouse button.
In the opened window select the Function block on the left-hand side. In the
example project, for
Name: TR_Manufacturer_Error
should be entered, for
Fail-safe:
deselect the
Create F-block
checkbox and for
Language:
FBD
should be set. For
Number: 170
must be manually entered in the example
project. As the block will be edited immediately after creation, the
Add new and
open
checkbox below
Additional information
must be ticked. The function
block is created and opened in the program editor by pressing the OK button.