Troubleshooting
Electrical Control
5
X
☆
X
X
Indoor temperature sensor is
abnormal
Recover automatically after
errors are eliminated (For T3
malfunction of 5HP, can
’
t
recover automatically)
6
☆
X
X
X
Evaporator temperature sensor is
abnormal
7
X
X
☆
X
Condenser temperature sensor is
abnormal
8
☆
☆
X
X
EEPROM malfunction
9
X
X
X
☆
Full-water malfunction
Note:
“
○
”
means on ,
“
X
”
means off,
“
☆
”
means flashes at 5Hz,
“
★
”
means flashes at 0.5Hz