13.
Check all connections for leaks.
WARNING: Both the
control box shield and
the access panel must
be reinstalled after
conversion/ installation
or servicing has been
completed. Failure to
do so will overheat and
cause premature failure
of the control system.
11. Remove the aluminum cap from the top
of the pressure regulator. (Fig. #88)
12.
Press down on the center post and rotate
90°. The center post should stay down.
(Fig. #89). Replace the aluminum cap.
14.
Fill in the date and the name of the person who performed the conversion in the white
area on the conversion label. Peel off the protective backing and apply the conversion
label directly over the gas specifi cations on the rating label.
15. Re-attach the access panel to the fl oor of the fi rebox with the screws previously removed
then replace the secondary fl oor and install or reinstall the burners, burner tray and
media.
Date:
______________________
By / Par:
___________________
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
11.0 in/wc / 11.0 po/c.e.
(2.74 kPa)
#51
Max.: 61,000Btu (17.8kw)
Min.: 39,000Btu (11.5kw)
120412 6-WS54ST 5052.52089
Kit # TCWS.54STLP for use with model: Pour
utilise avec du modèle:
TCWS54ST
This appliance was converted
t o P R O PA N E G A S w i t h
this kit on this date by the
organization which accepts
the responsibility that this
conversion has been properly
made. / Cet appariel etair
converter au gaz LP par l’emploi
de la trousse de conversion par
une organization qui accepte
la responsibilité pour une
installation en bon état.
ADD DATE
ADD NAME
Fig #88
Fig #89
NG
LP
Fig #90
46
TCWS.54CSTE 110712-72
Содержание TCWS54ST SERIES D