This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent
direct vent pipe, Selkirk Direct-temp vent pipe or ICC Exceldirect vent pipe
with a 5” inner pipe and an 8” outer pipe. For part numbers see the table of
venting components on page 19 of this manual. This vent can only be used
as a side wall termination.
1. Locate the power vent termination following the clearance to combustible table(Page 20
& Page 21), venting confi guration diagram (Fig. #26 & 27), and terminal location diagram
(Fig. #28).
2. Cut and frame a 14 1/2” wide by 14 3/4” high opening. For standard up and out
installations, the opening should be 3/4” lower than the minimum specifi ed in Fig. #27.
Height of the opening will vary with each installation.
3. Attach the power vent terminal, by securing the outer fl anges on the perimeter of the
terminal to the outside wall; ensure that the terminal is the right way up (exhaust at the
bottom). Once secured to the building, the outer fl anges may be covered with siding/
stucco etc. up to the level of the perimeter edge. As per local building codes. See Fig. #30.
4. For wall thicknesses 7 1/2” or less, install the inner wall plate supplied over the terminal
as shown in Fig#31 and secure to the framing. See Fig. #31.
CAUTION:
This terminal is designed to be
fi nished fl ush to the fi nished outside
wall; under no circumstances
should this terminal be recessed
into the wall past this point.
(Fig. #30)
Horizontal (Side Wall) Venting
CAUTION:
The rise and run combination and the
number of elbows must not exceed
specifi cations in Fig #26.
Fig. #29
Fig. #31
Fig. #30
TERMINAL SECURING
FLANGE
WALL FINISH NO
DEEPER THAN 1 1/2”
EXHAUST
14 3/4”
14 1/2”
INNER WALL PLATE
SEAL WITH SILICONE
ON ALL FOUR SIDES
9”
22
TCWS.54CSTE 110712-72