Fig #18
6.
Slide the pilot adjustment band over and
ensure that the hole in the orifi ce band
is showing.
Fig. #83 shows NG position
Fig. #84 shows LP position
.
7.
Remove the secondary fl oor on the
control compartment side and remove
the access panel, 9 screws, and set
aside.
9. Remove the minimum rate screw
located in the valve (Fig. #86).
The minimum rate screw is sealed with
an O-ring. Use a thin bladed
screwdriver to back the screw out past
the limit of the threading. At this point
a groove on the screw body will be
visible just above the valve body. Insert
a thin tool (knife blade or fi ne
screwdriver
blade) into the groove and
gently pry the screw up. It helps to
rotate the screw while lifting on it.
10.
Replace the minimum rate screw with the
one provided in the propane conversion
kit supplied with this fi replace. Ensure
that the screw is fully seated (Fig. #87).
Fig #83
Fig #86
Fig #87
NG POSITION
LP POSITION
Fig #84
Fig #85
45
TCWS.54CSTE 110712-72