TECHNICAL SPECIFICATIONS

 

- Single phase power-supply voltage 

115 / 230  VAC 

 

- Voltage variation tolerance 

+/- 10  % 

 

- Frequency 

50 / 60  Hz 

 

- Full load amp rating 115 VAC 

16  FLA 

 

- Full load amp rating 230 VAC 

20  FLA 

 

- Max working pressure 

174  psi 

 

- Pressure adjusting rangem

in   45   psi 

  

max  95  psi 

 

- Max working temperature 

149  ˚F (65˚C) 

 

- Inlet / Outlet connections 

1 ¼

  MPT 

 

- Threaded gauge connection 

¼”  FPT 

 

- Threaded conduit connections 

½

  FPT 

 

- Electronic box enclosure 

12  NEMA 

• 

Displays when power is connected to TOTAL CONTROL unit. 

• 

In the event of a temporary power outage, TOTAL CONTROL resets automatically when 
power is restored. 

• 

Displays when pump is running. 

• 

Displays when there is a problem with the system. 

• 

Press and hold to reset for 3-5 seconds ( with a tap opened ). Green “Power on” light and 
yellow “Pump on” should display. This indicates system is operating properly. 

• 

If red “Failure” light comes back on, refer to Troubleshooting Guide. 

OPERATION

TROUBLESHOOTING

MAINTENANCE AND SPARE PARTS

- 3 - 

Operating faults 

Main causes 

Pump does not start 

Check wiring connections. 

Check suction pipe, see page 6. 

Pump turns on and off (short-cycles) 

Leakage lower than minimum flow. 

Pump does not stop 

Leakage above minimum flow. 

No water flow 

Suction problems. 

Power on 

Pump on 

Failure 

Restart

( green ) 

( yellow ) 

( red ) 

( red ) 

In the case of a fault in the electronic box, this can be replaced without removing the device as it is inter-

changeable and supplied on request. 

Further malfunctioning can be avoided by checking the features  of the device,  pump  and system  with  the 

warnings indicated in the installation guidelines. 

Содержание PCTC16F16S

Страница 1: ...components Eliminates pump pressure switch Assists in absorbing water hammer Built in pressure and flow switch Can be used with or without pressure tank e m i t d n a e c a p s s e v a s n o i t a l l...

Страница 2: ...ical connections 9 Installation wiring diagram 115 VAC 2 wire pumps up to 16 FLA 9 Installation wiring diagram 230 VAC 2 wire pumps up to 20 FLA 10 Installation wiring diagram 230 VAC 3 wire pumps up...

Страница 3: ...stem and disconnect power supply before installing or servicing TOTAL CONTROL Make sure line voltage and frequency of power supply match motor nameplate voltage and frequency and TOTAL CONTROL voltage...

Страница 4: ...and hold to reset for 3 5 seconds with a tap opened Green Power on light and yellow Pump on should display This indicates system is operating properly If red Failure light comes back on refer to Troub...

Страница 5: ...it without use of liquid tight conduit voids warranty 4 Do not over thighten water connections especially when installing with metal couplings Damage to TOTAL CONTROL may result Prepare all threads wi...

Страница 6: ...INSTALLATION ON SURFACE AND SUBMERSIBLE PUMPS If pressure exceeds 174 psi install a pressure reducing valve SURFACE PUMP TOTAL CONTROL can be installed on surface and submersible pumps for residential...

Страница 7: ...oltage Must always be installed in the vertical position flow arrows up electronic box level Do not install any tap or tee between the pump and the TOTAL CONTROL Install a gate valve after the TOTAL C...

Страница 8: ...m pressure can be adjusted between minimum 45 psi and maximum 95 psi Open a tap to start up the pump close the tap and wait for pump to stop then check the system pressare on the pressure gauge normal...

Страница 9: ...AL CONTROL P3 If the pressure of the pump P1 fails to reach the values indicated in the pressure adjustment table the pump will stop working In the event of the height of the water column P3 being hig...

Страница 10: ...of pump and supply to determine pump motor FLA and follow applicable TOTAL CONTROL wiring diagram If pump motor FLA exceeds TOTAL CONTROL rating use magnetic starter wiring diagram for the applicable...

Страница 11: ...INSTALLATION WIRING DIAGRAM 230VAC 2 WIRE PUMPS UP TO 20 FLA INSTALLATION WIRING DIAGRAM 230VAC 3 WIRE PUMPS UP TO 20 FLA 10...

Страница 12: ...exceed 16 FLA On 230V installations pump motor full load amps exceed 20 FLA On all three phase applications Remember match coil voltage on contactor with TOTAL CONTROL voltage Either 115V or 230V coil...

Страница 13: ...230 VAC THREE PHASE 3 WIRE PUMPS INSTALLATION WIRING DIAGRAM 460VAC For 460Vac motors use magnetic starter to avoid damage to TOTAL CONTROL 12 For 208Vac or 230Vac three phase motors use magnetic sta...

Страница 14: ...OVERALL DIMENSIONS 13 INSTALLATION WIRING DIAGRAM 230VAC 3 WIRE PUMPS EXCEEDING 20 FLA...

Страница 15: ...will not operate WARNING Do not turn on power until the box cover has been securely fastened 4 Install the new electronic box and tighten the three screws Do not overthighten or damage to t hreads may...

Страница 16: ...OTAL CONTROL is warranted to be free of defects occurring either in hydraulic or electronic parts for a period of one year from the date of installation when installed by a licensed professional in ac...

Отзывы: