TECHNICAL SPECIFICATIONS
- Single phase power-supply voltage
115 / 230 VAC
- Voltage variation tolerance
+/- 10 %
- Frequency
50 / 60 Hz
- Full load amp rating 115 VAC
16 FLA
- Full load amp rating 230 VAC
20 FLA
- Max working pressure
174 psi
- Pressure adjusting rangem
in 45 psi
max 95 psi
- Max working temperature
149 ˚F (65˚C)
- Inlet / Outlet connections
1 ¼
”
MPT
- Threaded gauge connection
¼” FPT
- Threaded conduit connections
½
”
FPT
- Electronic box enclosure
12 NEMA
•
Displays when power is connected to TOTAL CONTROL unit.
•
In the event of a temporary power outage, TOTAL CONTROL resets automatically when
power is restored.
•
Displays when pump is running.
•
Displays when there is a problem with the system.
•
Press and hold to reset for 3-5 seconds ( with a tap opened ). Green “Power on” light and
yellow “Pump on” should display. This indicates system is operating properly.
•
If red “Failure” light comes back on, refer to Troubleshooting Guide.
OPERATION
TROUBLESHOOTING
MAINTENANCE AND SPARE PARTS
- 3 -
Operating faults
Main causes
Pump does not start
Check wiring connections.
Check suction pipe, see page 6.
Pump turns on and off (short-cycles)
Leakage lower than minimum flow.
Pump does not stop
Leakage above minimum flow.
No water flow
Suction problems.
Power on
Pump on
Failure
Restart
( green )
( yellow )
( red )
( red )
In the case of a fault in the electronic box, this can be replaced without removing the device as it is inter-
changeable and supplied on request.
Further malfunctioning can be avoided by checking the features of the device, pump and system with the
warnings indicated in the installation guidelines.