DOMESTIC PUMP CONTROL 

SUBMERSIBLE  PUMPS 

JET  PUMPS 

BOOSTER  PUMPS 

WARRANTY

THE WARRANTY PERIOD IS ONE YEAR FROM INSTALLATION DATE 

WARRANTY AND DISCLAIMER OF WARRANTY 

The following warranty for the product is in lieu of all other conditions or warranties, whether express, implied 

or statutory, including but not limited to any implied conditions or warranties of merchantability or fitness for a 

particular  purpose  and  on  any  implied  conditions  or  warranty  obligation  on  the  part  of  manufacturer  or  its 

distributors,  which  are  hereby  expressly  disclaimed. TOTAL  CONTROL  is  warranted  to  be  free  of defects 

occurring either  in  hydraulic or  electronic  parts  for a period of one  year  from  the date  of  installation when 

installed  by  a  licensed  professional  in  accordance  with  the  product  manual  and  due  professional  care. 

PATENT INFRINGEMENT

Our devices are protected under world-wide patents including the United States Patent Office. Any violation 

and or attempt to copy the products in any part or form to the extent such copying or duplication in any part 

or form infriges upon the patents will be swiftly and aggressively prosecuted. 

U.S. Patent 5,259,733. 

™ 

Re

v.

 CP09 

05

.0

Locally distributed by: 

3000 W 16Th Ave.

Miami, Florida 33012   

ph. 001 954 474 9090 

fax 001 954 889 0413 

www.pdwatersystems.com 

PD WATER SYSTEMS

Содержание PCTC16F16S

Страница 1: ...components Eliminates pump pressure switch Assists in absorbing water hammer Built in pressure and flow switch Can be used with or without pressure tank e m i t d n a e c a p s s e v a s n o i t a l l...

Страница 2: ...ical connections 9 Installation wiring diagram 115 VAC 2 wire pumps up to 16 FLA 9 Installation wiring diagram 230 VAC 2 wire pumps up to 20 FLA 10 Installation wiring diagram 230 VAC 3 wire pumps up...

Страница 3: ...stem and disconnect power supply before installing or servicing TOTAL CONTROL Make sure line voltage and frequency of power supply match motor nameplate voltage and frequency and TOTAL CONTROL voltage...

Страница 4: ...and hold to reset for 3 5 seconds with a tap opened Green Power on light and yellow Pump on should display This indicates system is operating properly If red Failure light comes back on refer to Troub...

Страница 5: ...it without use of liquid tight conduit voids warranty 4 Do not over thighten water connections especially when installing with metal couplings Damage to TOTAL CONTROL may result Prepare all threads wi...

Страница 6: ...INSTALLATION ON SURFACE AND SUBMERSIBLE PUMPS If pressure exceeds 174 psi install a pressure reducing valve SURFACE PUMP TOTAL CONTROL can be installed on surface and submersible pumps for residential...

Страница 7: ...oltage Must always be installed in the vertical position flow arrows up electronic box level Do not install any tap or tee between the pump and the TOTAL CONTROL Install a gate valve after the TOTAL C...

Страница 8: ...m pressure can be adjusted between minimum 45 psi and maximum 95 psi Open a tap to start up the pump close the tap and wait for pump to stop then check the system pressare on the pressure gauge normal...

Страница 9: ...AL CONTROL P3 If the pressure of the pump P1 fails to reach the values indicated in the pressure adjustment table the pump will stop working In the event of the height of the water column P3 being hig...

Страница 10: ...of pump and supply to determine pump motor FLA and follow applicable TOTAL CONTROL wiring diagram If pump motor FLA exceeds TOTAL CONTROL rating use magnetic starter wiring diagram for the applicable...

Страница 11: ...INSTALLATION WIRING DIAGRAM 230VAC 2 WIRE PUMPS UP TO 20 FLA INSTALLATION WIRING DIAGRAM 230VAC 3 WIRE PUMPS UP TO 20 FLA 10...

Страница 12: ...exceed 16 FLA On 230V installations pump motor full load amps exceed 20 FLA On all three phase applications Remember match coil voltage on contactor with TOTAL CONTROL voltage Either 115V or 230V coil...

Страница 13: ...230 VAC THREE PHASE 3 WIRE PUMPS INSTALLATION WIRING DIAGRAM 460VAC For 460Vac motors use magnetic starter to avoid damage to TOTAL CONTROL 12 For 208Vac or 230Vac three phase motors use magnetic sta...

Страница 14: ...OVERALL DIMENSIONS 13 INSTALLATION WIRING DIAGRAM 230VAC 3 WIRE PUMPS EXCEEDING 20 FLA...

Страница 15: ...will not operate WARNING Do not turn on power until the box cover has been securely fastened 4 Install the new electronic box and tighten the three screws Do not overthighten or damage to t hreads may...

Страница 16: ...OTAL CONTROL is warranted to be free of defects occurring either in hydraulic or electronic parts for a period of one year from the date of installation when installed by a licensed professional in ac...

Отзывы: