E6581158
C-4
3
3.1.2 How to set the frequency
[Example of a
HOQF
setting procedure]
Key operated
LED display
Operation
Displays the operation frequency (operation stopped).
(When standard monitor display selection
H
=
ҏ
[Operation
frequency])
CWJ
Displays the first basic parameter [History (
CWJ
)].
HOQF
Press either the key or key to select “
HOQF
”.
Press ENTER key to display the parameter setting. (Default setting:
).
Change the parameter to
(Operation panel) by pressing the key.
ҏ
⇔
HOQF
Press the ENTER key to save the changed parameter.
HOQF
and the
parameter set value are displayed alternately.
*
Pressing the MODE key twice returns the display to standard monitor mode (displaying operation frequency).
(1)
Setting the frequency using the potentiometer on the inverter main unit
(
HOQF
=
)
Set the frequency with the notches on the potentiometer.
Move clockwise for the higher frequencies.
The potentiometer has hysteresis. So the set value may slightly change
when the inverter is turned off, and then turned back on.
(2)
Setting the frequency using the operation panel
(
HOQF
=
)
Set the frequency with the operation panel..
: Moves the frequency up
: Moves the frequency down
MODE