14-5
5. Protection Circuit Diagnosis Procedure
• When the overvoltage protection circuit is working, never turn on the power with the protection circuit disable.
High voltage will be stepped up and secondary breakdown may occur.
Operation of protection
circuit for Thyristor D862
(SR81 relay turns on but
immediately turns off.)
Power on with D870
opened. (Do not turn on
for a long period.)
SR81 turns on.
SR81 turns on for a short time
but immediately turns off.
With SW turned on,
check 180V line voltage
with oscilloscope.
Less than 205V
With SW turned on,
check 20V line voltage
with oscilloscope.
Less than 35V
With SW turned on,
check voltage across
C471 with oscilloscope.
Less than 42V
Check C867, D862, D878,
Q863, R875, R877, and
repair.
Higher than 205V
Higher than 42V
Higher than 35V
Check over-current protection
circuit, H deflection circuit and
D870, Q870, R870-R873, R876,
and repair.
Check error-amp circuit QQ08,
QQ03, QQ02, QQ01, DQ13,
DQ14, and repair. Check broken
pattern in feedback loop.
Check pattern connectors
connected to Q601, and repair.
Check X-ray protection circuit,
H output circuit, X-ray protection
detector circuit, and repair.