![Toshiba MM20E45 Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/toshiba/mm20e45/mm20e45_technical-training-manual_1138456069.webp)
10-3
3. X-RAY PROTECTION CIRCUIT–2
This is protection circuit peculiar to this model, and which
separates a detecting circuit and is equipped with the circuit
to be lead in operation stop, perfectly to be independent of the
circuit of section 9-2.
The detecting voltage is produced by peak-rectifying of
pulse at pin 6 on FBT. When the voltage X-2 divided from
the detecting voltage exceeds the value { zener voltage(36V)
of DH15 + gate voltage (0.6V) of SCR DH14 } , these turn
on to let operation of hor deflection circuit stop. Turning on
of QH45 make short to ground the trigger pulse which is
supplied from QK14 to chopper regulators of deflection
circuit and high voltage circuit, and for the reason, the both
circuits stop operation to prevent X-ray radiation. Once this
circuit operates, the situation is held until power switch is
turned off.
Fig. 3
5
6
4
D471
R469
D474
C471
C472
X-Ray Protector-1
ICH08
LA7860
16
+12V
R466
DH14
DH15
R474
R475
R473
R467
CK32
R468
QH45
X-2
R-2
+12V
QK07
QK14
ICK01
TA755P
ICH20
TA7555P
Deflection Control
Chopper Regulator
High Voltage Control
Chopper Regulator
2
2
Trigger
pulse