1 3 - 8
3-3 Overvoltage Protection Circuit
The 182V line voltage will increase to about over 215V when
the error amplifier failure occurs, etc. It is hazardous to
supply the power to loads under such a condition. To prevent
the hazard, an overvoltage protection circuit is provided to
open the AC relay SR81 and to stop oscillation of the power.
The 182V line voltage is always monitored with R878, R879
and R880. When the divided voltage exceeds a specified
voltage level, a zener diode D878 turns on, and this triggers
D862, and D862 and Q863 are turned on. Then, the relay on/
off transistor turns off and opens the AC relay, thus the power
supply circuit stops the oscillation.
3-4 Overcurrent Protection Circuit
The overcurrent protection circuit is also provided to open
the AC relay SR81 and to stop oscillation of the power.
The 182V line load is always monitored with R876. When
the voltage of R876 exceeds the bias of Q870 V
BE
(about
1.0V), Q870 and D870 turn on and these trigger D862.
Then the power supply circuit stops the oscillation all the
same as the above 3-3. overvoltage protection circuit.
R876
Q870
R879
R880 R875
R870
R878
C871
R874
R871
R877
Q863
Q862
SR81
D878
C867
D862
182V load current
QH24
chopper
regulator
Normally
ON
Relay
ON/OFF
Tr
182V Line
D870
Relay
ON/OFF
Fig. 13-16